Viessmann · Vitodens 200-W (B2HA, 285–530 MBH)
Viessmann Vitodens 200-W B2HA-352
The Vitodens 200-W B2HA-352 is the largest model in the 194 lb B2HA cabinet: 71,000 to 352,000 BTU (21 to 103 kW) of input at a printed 94.5% thermal-efficiency row (ANSI Z21,13/CSA 4.9), for the biggest loads that still fit one wall-hung boiler.
Key figures
- Max input
- 352 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 71 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Viessmann Vitodens 200-W B2HA-352 in practice
The B2HA-352 tops out the mid chassis of the Vitodens 200-W B2HA line at 352,000 BTU (103 kW) maximum input while keeping the 71,000 BTU (21 kW) minimum fire shared with the B2HA-285 and B2HA-311. It is the largest model that stays in the 194 lb (88 kg), 19 x 21 x 43½ inch (480 x 530 x 1105 mm) cabinet — the B2HA-399 and B2HA-530 step up to the 298 lb chassis.
The page's spec table prints the B2HA-352's efficiency as a thermal-efficiency row of 94.5% per ANSI Z21,13/CSA 4.9, matching the B2HA-311's printed row. Page marketing copy separately cites an 'up to 95% AFUE rating' for the product line, so the printed spec-row figure is kept on this record.
The boiler is gas-fired and wall-mounted with the MatriX cylinder burner and Inox-Radial stainless steel heat exchanger, and Viessmann Canada lists it for natural gas or liquid propane with no fuel-conversion kit required. The page's technical table mixes legacy B2HB rows with the B2HA rows; only the B2HA-352 figures are used here.
Best suited to
- Large homes and light-commercial plants whose load calculation approaches 352 MBH
- Projects that want maximum wall-hung input before stepping to the 298 lb B2HA chassis
- Cascaded plants where four units can common-vent (series-level option per the page)
Applicability and support
- Model number
- B2HA-352
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum (natural gas) | 71 MBH | 71,000 BTU (21 kW), per the Canadian product page |
| Input, maximum (natural gas) | 352 MBH | 352,000 BTU (103 kW), per the Canadian product page |
| Efficiency | ||
| Thermal efficiency (ANSI Z21,13/CSA 4.9) | 94.5 % | 94.5% for the B2HA-352 spec row on the Canadian product page. |
| Venting and air | ||
| Maximum vent run | 180 ft | Vent length up to 180 ft per the Canadian product page; common venting of up to four boilers is a series-level option. |
| Physical and connections | ||
| Weight | 194 lb | 88 kg |
| Width | 19 in | 480 mm |
| Depth | 21 in | 530 mm |
| Height | 43.5 in | 1105 mm |
| Operating limits and other | ||
| Fuel type | Natural gas (NG) or liquid propane gas (LPG) | No fuel-conversion kit required per the Canadian product page. |
Manuals
Alerts documented for this model
- 0F
- 10
- 18
- 1A
- 1B
- 1F
- 20
- 28
- 30 140
- 38 140
- 40
- 44
- 48
- 4C
- 50
- 51
- 58
- 59
- 90
- 91
- 92
- 93
- 94
- 98
- 99
- 9A
- 9B
- 9C
- 9E
- 9F
- A3
- A4
- A7
- B0 141
- B1
- B5
- B7
- B8 141
- BA
- BB
- BC
- BD
- BE
- BF
- C1
- C2
- C3
- C4
- C5
- CD
- CF
- D6
- D7
- D8
- DA
- DB
- DC
- DD
- DE
- DF
- E0
- E1 202
- E2 201
- E3 204
- E4
- E5 226
- E7 192
- E8 189
- EA 193
- EB 194
- EC 67 or 195
- ED 191
- EE 132
- EF 138
- F0
- F1 135
- F2 129
- F3 139
- F6
- F8 148
- F9 151 or 152
- FA 154
- FC 190
- FD 227
- FD -
- FE 158, 159, 162 or 225
- FF 224
- N/A 2
- N/A 3
- N/A 5
- N/A 6
- N/A 8
- N/A 29
- N/A 33
Frequently asked questions
What is the B2HA-352's firing range?
From a 71,000 BTU (21 kW) minimum input up to 352,000 BTU (103 kW) maximum on natural gas, per the Canadian product page — the top of the 194 lb B2HA cabinet.
How efficient is the B2HA-352?
The page prints a 94.5% thermal-efficiency row (ANSI Z21,13/CSA 4.9) for the B2HA-352, the same figure it prints for the B2HA-311. Marketing copy on the same page separately cites an 'up to 95% AFUE rating'.
When should I step up to the B2HA-399?
When the heat-loss calculation needs more than 352 MBH: the B2HA-399 and B2HA-530 move to the 298 lb (135 kg) cabinet and fire from a higher 113,000 BTU (33 kW) minimum input.
Questions about the Viessmann Vitodens 200-W B2HA-352?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Viessmann Vitodens 200-W B2HA-311 vs B2HA-352Comparison
- Viessmann Vitodens 200-W B2HA-352 vs B2HA-399Comparison
- Viessmann Vitodens 200-W B2HA-285Same series
- Viessmann Vitodens 200-W B2HA-311Same series
- Viessmann Vitodens 200-W B2HA-399Same series
- Viessmann Vitodens 200-W B2HA-530Same series
- Vitodens 200-W (B2HA, 285–530 MBH) series hub
- Buying guide
Sources and verification
- Viessmann Canada — Vitodens 200-W, B2HA/B2HB product page · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.