Viessmann · Vitodens 222-F (B2TA)

Viessmann Vitodens 222-F B2TA 35

The Vitodens 222-F B2TA 35 is the larger of the two earlier-generation 222-F combis: 19 to 125 MBH NG/LPG input at 93.3% AFUE with an integrated 26.5 USG (100 L) DHW tank and a 3.3 USG/min continuous draw at a 70°F rise.

DiscontinuedHistorically in Canada

Key figures

Max input
125 MBH
Max CSA output
—
AFUE
93.3 %
Min input
19 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 222-F B2TA 35 in practice

The B2TA 35 is the larger B2TA combi: 19-125 MBH (5.5-37 kW) NG/LPG input, 17.4-114 MBH (5.1-33 kW) output, a 99 MBH (29 kW) Net AHRI rating and 93.3% AFUE. It carries the same 26.5 USG (100 L) integrated stainless steel DHW tank as the B2TA 19, with a 150 psig maximum allowable potable-water pressure.

Its DHW delivery is nearly double the smaller model's: a 3.3 USG/min continuous draw and a 60 USG maximum 10-minute draw at a 70°F rise, with the same 4,435 BTU/24h standby loss. Weight (282 lb / 128 kg) and dimensions (595 x 600 x 1625 mm) are identical to the B2TA 19, and the model must not be common-vented with any other appliance.

Best suited to

  • Owners of existing B2TA 35 combis checking printed ratings and DHW figures
  • Homes whose hot-water demand needs the 3.3 USG/min continuous draw
  • Comparing the B2TA 35 against the later B2TB-125 and the B2HE boilers

Applicability and support

Model number
B2TA 35
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 222-F B2TA 35 specifications
SpecificationValueNote
Input
CSA input, minimum (NG/LPG)19 MBH5.5 kW, per the technical data manual
CSA input, maximum (NG/LPG)125 MBH37 kW, per the technical data manual
Output
CSA output / DOE heating capacity17.4-114 MBH5.1-33 kW, based on 140°F / 120°F supply/return
Net AHRI rating99 MBH29 kW; based on piping and pick-up allowance of 1.15.
Efficiency
Efficiency (AFUE)93.3 %93.3% AFUE on both B2TA models per the technical data manual.
Domestic hot water
Integrated DHW tank26.5 USG (100 L)Stainless steel tank; 150 psig maximum allowable potable-water pressure.
Continuous DHW draw at 70°F rise3.3 USG/minBased on a 70°F (21K) rise, 50°F to 120°F, per the technical data manual.
Maximum DHW draw over 10 minutes60 USGBased on a 70°F (21K) rise.
DHW standby loss4,435 BTU/24h184 BTU/h, 0.8°F/h at 68°F room and 149°F DHW.
Domestic hot waterCombi: space heating and DHW with an integrated storage tank
Physical and connections
Weight282 lb128 kg
Width600 mm
Depth595 mm
Height1,625 mm64 in; add 40 mm with the optional seismic bracket kit.
Operating limits and other
FuelNatural gas or liquid propane gas
Boiler water content0.87 USG3.27 L
Maximum operating pressure45 psigAt 210°F (99°C); 3 bar.

Frequently asked questions

What is the input range of the B2TA 35?

19-125 MBH (5.5-37 kW) NG/LPG input, 17.4-114 MBH (5.1-33 kW) output, a 99 MBH Net AHRI rating and 93.3% AFUE, per the technical data manual.

How much hot water does the B2TA 35 deliver?

A 3.3 USG/min continuous draw and a 60 USG maximum 10-minute draw at a 70°F rise, from its integrated 26.5 USG (100 L) DHW tank.

How does the B2TA 35 differ from the B2TA 19?

Both share the tank, weight and cabinet; the 35 fires to 125 MBH against the 19's 67 MBH and doubles the continuous DHW draw from 1.8 to 3.3 USG/min.

Questions about the Viessmann Vitodens 222-F B2TA 35?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate