Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitocrossal 300 (CA3B)

Viessmann Vitocrossal 300 CA3B 2.5

The Vitocrossal 300 CA3B 2.5 is the entry size of Viessmann Canada's large commercial CA3B range: 250,000 to 2,500,000 BTU (73 to 733 kW) of natural-gas input at 96.1% thermal efficiency, rated for 160 psi, in a 4233 lb (1920 kg) floor-standing boiler.

CurrentSold in Canada

Key figures

Max input
2,500 MBH
Max CSA output
—
AFUE
—
Min input
250 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitocrossal 300 CA3B 2.5 in practice

The CA3B 2.5 is the smallest of the six Vitocrossal 300 CA3B sizes. The product page prints its natural-gas input from 250,000 BTU (73 kW) minimum to 2,500,000 BTU (733 kW) maximum, and all CA3B models print 96.1% thermal efficiency.

The boiler is rated for 160 psi maximum operating pressure and weighs 4233 lb (1920 kg) as a single-fuel unit. It is a floor-standing commercial condensing boiler with an SA240 316Ti stainless steel Inox-Lamellar heat exchanger and fully modulating pre-mix cylinder burners, controlled by the Vitotronic 300 GW6C.

Like every CA3B size it supports common venting of up to four boilers, sealed-combustion or room-air-dependent sidewall or chimney venting, dual-fuel (NG/LP) models with key changeover, altitude operation to 10,000 ft and disassembly into sections for narrow doorways. The page lists no manual downloads for this record's scope.

Best suited to

  • Large commercial plants whose design load fits within 2500 MBH of input
  • High-pressure (160 psi) hydronic systems on the CA3B platform
  • Projects stepping into the CA3B range at its smallest, 4233 lb size

Applicability and support

Model number
CA3B 2.5
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitocrossal 300 CA3B 2.5 specifications
SpecificationValueNote
Input
Minimum input (natural gas)250 MBH250,000 BTU (73 kW), per the product page
Maximum input (natural gas)2,500 MBH2,500,000 BTU (733 kW), per the product page
Efficiency
Thermal efficiency96.1 %96.1% on all CA3B models (page/TDM: AHRI 1500 / DOE / ANSI Z21.13-CSA 4.9 / BTS-2000).
Physical and connections
Weight, single fuel4,233 lb1920 kg
Operating limits and other
Maximum operating pressure160 psig160 psi per the product page; the printed data lists a 210°F high limit.

Manuals

    Alerts documented for this model

    None documented yet.

    Services

    Frequently asked questions

    What is the firing range of the CA3B 2.5?

    Natural-gas input from 250,000 BTU (73 kW) minimum to 2,500,000 BTU (733 kW) maximum, per the product page; maximum input is 2500 MBH.

    What efficiency does the CA3B 2.5 print?

    96.1% thermal efficiency, the figure printed for all six CA3B models (AHRI 1500 / DOE / ANSI Z21.13-CSA 4.9 / BTS-2000).

    How heavy is the CA3B 2.5?

    4233 lb (1920 kg) as a single-fuel unit per the product page, with a 160 psi maximum operating pressure rating.

    Questions about the Viessmann Vitocrossal 300 CA3B 2.5?

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate