The Vitocrossal 300 CA3B is Viessmann Canada's largest current commercial gas condensing boiler series: models CA3B 2.5 to 6.0 at 2500 to 6000 MBH maximum input, 96.1% thermal efficiency, rated for 160 psi, with an Inox-Lamellar stainless steel heat exchanger and the Vitotronic 300 GW6C control.

Current seriesSold in CanadaNatural gasPropanecommercial

Series facts

Type
condensing
Efficiency
96.1% thermal-efficiency
Fuel
Natural gas or liquid propane; dual-fuel (NG/LP) models are available with key changeover. NG supply pressure is 4–14 in. w.c. and LPG 10–14 in. w.c. per the technical data manual, which also prints separate, higher LPG minimum inputs.
Venting
Common venting of up to four boilers; sidewall or chimney configurations, with sealed combustion or room-air-dependent operation, per the product page.
Models documented
6
Warranty
Not verified

96.1% on all CA3B models per the product page and technical data manual (AHRI 1500 / DOE / ANSI Z21.13-CSA 4.9 / BTS-2000).

About the Vitocrossal 300 (CA3B)

The Vitocrossal 300 CA3B is a gas-fired, floor-standing commercial condensing boiler with an SA240 316Ti stainless steel Inox-Lamellar heat exchanger and up to three fully modulating pre-mix cylinder burners. It is rated for 160 psi operation and is positioned by Viessmann Canada as its flagship large commercial boiler — the page cites the First Canadian Place installation in Toronto — with common venting of up to four boilers and sidewall or chimney venting in sealed-combustion or room-air-dependent configurations.

The six Canadian sizes are CA3B 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0, with maximum inputs of 2500 to 6000 MBH (733 to 1758 kW) and printed natural-gas minimums of 250, 300, 300, 400, 300 and 400 MBH respectively. All models print 96.1% thermal efficiency, and the page cites total burner modulation 'up to 16:1 per boiler'. The boiler disassembles into sections for narrow doorways and elevators, and dual-fuel (NG/LP) models are available with key changeover.

The control is a Vitotronic 300, GW6C (with the HI932 user interface on current units), running single-boiler or cascade primary/secondary control with outdoor reset; it regulates one high-temperature circuit, two mixing-valve circuits and one DHW circuit, with BMS connectivity via LON or a gateway. Low inlet NG pressure from 4 in. w.c., altitude operation to 10,000 ft, and a limited 10-year commercial warranty complete the page picture.

Highlights

  • Six commercial sizes: CA3B 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0, at 2500 to 6000 MBH maximum input
  • 96.1% thermal efficiency on all models (AHRI 1500 / DOE / ANSI Z21.13-CSA 4.9 / BTS-2000)
  • Rated for 160 psi; SA240 316Ti stainless steel Inox-Lamellar heat exchanger
  • Up to three fully modulating pre-mix cylinder burners; 'up to 16:1' modulation per boiler
  • Vitotronic 300 GW6C control (HI932 interface); common venting of up to four boilers
  • Dual-fuel (NG/LP) models with key changeover; limited 10-year commercial warranty

Models

Vitocrossal 300 (CA3B) models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
250–2500 MBH
Output (max)
—
AFUE
—

The Vitocrossal 300 CA3B 2.5 is the entry size of Viessmann Canada's large commercial CA3B range: 250,000 to 2,500,000 BTU (73 to 733 kW) of natural-gas input at 96.1% thermal efficiency, rated for 160 psi, in a 4233 lb (1920 kg) floor-standing boiler.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
300–3000 MBH
Output (max)
—
AFUE
—

The Vitocrossal 300 CA3B 3.0 is the 3000 MBH size of the CA3B range: 300,000 to 3,000,000 BTU (88 to 879 kW) of natural-gas input at 96.1% thermal efficiency, rated for 160 psi, in the same 4233 lb (1920 kg) unit as the CA3B 2.5.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
300–3500 MBH
Output (max)
—
AFUE
—

The Vitocrossal 300 CA3B 3.5 is the 3500 MBH size of the CA3B range: 300,000 to 3,500,000 BTU (88 to 1026 kW) of natural-gas input at 96.1% thermal efficiency, rated for 160 psi, weighing 4696 lb (2130 kg).

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
400–4000 MBH
Output (max)
—
AFUE
—

The Vitocrossal 300 CA3B 4.0 is the 4000 MBH size of the CA3B range: 400,000 to 4,000,000 BTU (117 to 1172 kW) of natural-gas input at 96.1% thermal efficiency, rated for 160 psi, weighing 4806 lb (2180 kg).

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
300–5000 MBH
Output (max)
—
AFUE
—

The Vitocrossal 300 CA3B 5.0 is the 5000 MBH size of the CA3B range: 300,000 to 5,000,000 BTU (88 to 1465 kW) of natural-gas input at 96.1% thermal efficiency, rated for 160 psi, in a 6261 lb (2840 kg) unit.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
400–6000 MBH
Output (max)
—
AFUE
—

The Vitocrossal 300 CA3B 6.0 tops the CA3B range at 6000 MBH: 400,000 to 6,000,000 BTU (117 to 1758 kW) of natural-gas input at 96.1% thermal efficiency, rated for 160 psi, in the range's heaviest 6894 lb (3127 kg) unit.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Viessmann Vitocrossal 300 CA3B 2.5 and Viessmann Vitocrossal 300 CA3B 3.0 and Viessmann Vitocrossal 300 CA3B 3.5 and Viessmann Vitocrossal 300 CA3B 4.0 and Viessmann Vitocrossal 300 CA3B 5.0 and Viessmann Vitocrossal 300 CA3B 6.0
SpecificationViessmann Vitocrossal 300 CA3B 2.5Viessmann Vitocrossal 300 CA3B 3.0Viessmann Vitocrossal 300 CA3B 3.5Viessmann Vitocrossal 300 CA3B 4.0Viessmann Vitocrossal 300 CA3B 5.0Viessmann Vitocrossal 300 CA3B 6.0
Minimum input (natural gas)250 MBH300 MBH300 MBH400 MBH300 MBH400 MBH
Maximum input (natural gas)2,500 MBH3,000 MBH3,500 MBH4,000 MBH5,000 MBH6,000 MBH
output-max——————
afue——————
turndown——————
vent-max-3——————
vent-max-2——————
Weight, single fuel4,233 lb4,233 lb4,696 lb4,806 lb6,261 lb6,894 lb

Read the full comparison: Viessmann Vitocrossal 300 CA3B 2.5 vs CA3B 3.0 →

Read the full comparison: Viessmann Vitocrossal 300 CA3B 3.0 vs CA3B 3.5 →

Read the full comparison: Viessmann Vitocrossal 300 CA3B 3.5 vs CA3B 4.0 →

Read the full comparison: Viessmann Vitocrossal 300 CA3B 4.0 vs CA3B 5.0 →

Error codes and alerts

Vitocrossal 300 (CA3B) alerts

No alerts documented for this series yet.

Manuals

Official documents

    Where ROMA provides on-site service

    On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

    See all service areas

    Frequently asked questions

    Which Vitocrossal 300 CA3B models are sold in Canada?

    Six sizes per Viessmann Canada: CA3B 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0. Natural-gas minimum inputs print at 250 to 400 MBH per model, and maximum inputs run 2500 MBH (CA3B 2.5) up to 6000 MBH (CA3B 6.0).

    What efficiency and pressure rating does the CA3B carry?

    All six models print 96.1% thermal efficiency (AHRI 1500 / DOE / ANSI Z21.13-CSA 4.9 / BTS-2000). The page rates the boiler for 160 psi maximum operating pressure; the printed data also lists a 210°F high limit.

    How is the CA3B controlled?

    By a Vitotronic 300 GW6C boiler/system control with the HI932 user interface on current units: single-boiler or cascade primary/secondary control with outdoor reset, regulating one high-temperature circuit, two mixing-valve circuits and one DHW circuit.

    Talk to a boiler technician

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate