Viessmann · Vitocrossal 300 (CU3A)
Viessmann Vitocrossal 300 CU3A-199
The Vitocrossal 300 CU3A-199 is the largest model of Viessmann Canada's floor-standing CU3A line: 43,000 to 199,000 BTU (12.6 to 58 kW) of input at 95% AFUE, weighing 352 lb (160 kg), with a 5:1 turndown MatriX dome gas burner.
Key figures
- Max input
- 199 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 43 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Viessmann Vitocrossal 300 CU3A-199 in practice
The CU3A-199 tops the CU3A range at 199,000 BTU (58 kW) maximum input — the line's rated input runs 19 to 199 MBH overall — while keeping the 43,000 BTU (12.6 kW) minimum fire it shares with the CU3A-160. It is rated 95% AFUE, weighs 352 lb (160 kg) and shares the 31½-inch-deep (801 mm) cabinet with the CU3A-160.
Like the rest of the series it is a floor-standing condensing boiler with a vertical stainless steel Inox-Crossal heat exchanger, a MatriX dome gas burner with Lambda Pro combustion control and a Vitotronic 200 control, operating up to 194°F (90°C) and up to 10,000 ft (3,000 m) of altitude, per the page.
The page positions the CU3A for large homes and retrofit applications with high-mass radiators or high DHW demand, and for multi-boiler plants: installations can run up to 1592 MBH with no dedicated boiler pump required. The service instructions (doc 5673 649 - 20, dated 03/2025) cover Canadian models 26 to 199, including the CU3A-199.
Best suited to
- The largest single CU3A loads — up to 199,000 BTU (58 kW) of input
- Multi-boiler plants building toward the page's 1592 MBH installation ceiling
- Retrofits and new construction pairing high-mass radiators or high DHW loads with a floor-standing condensing boiler
Applicability and support
- Model number
- CU3A-199
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 43 MBH | 43,000 BTU (12.6 kW), per the Canadian product page |
| Input, maximum | 199 MBH | 199,000 BTU (58 kW), per the Canadian product page |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% for all models per the Canadian product page. |
| Venting and air | ||
| Maximum vent run | 198 ft | Vent lengths up to 198 ft per the Canadian product page. |
| Physical and connections | ||
| Weight | 352 lb | 160 kg |
| Width | 26 in | 660 mm |
| Depth | 31.5 in | 801 mm |
| Height | 61.5 in | 1562 mm with the control interface closed; 67 in (1707 mm) with it open |
| Operating limits and other | ||
| Turndown ratio | 5:1 | Per the Canadian product page. |
| Maximum altitude | 10,000 ft | High-altitude operation up to 10,000 ft (3,000 m) per the Canadian product page; the page prints no derating note. |
| Fuel type | Natural gas (NG) or liquid propane gas (LPG) | As printed on the Canadian product page. |
Manuals
Alerts documented for this model
Frequently asked questions
What is the firing range of the CU3A-199?
From a 43,000 BTU (12.6 kW) minimum input up to 199,000 BTU (58 kW) maximum, per the Canadian product page — the same minimum fire as the CU3A-160 with 39 MBH more ceiling.
Is the CU3A-199 bigger than the CU3A-160?
No. Both weigh 352 lb (160 kg) and share the same cabinet dimensions; only the maximum input differs — 199,000 BTU (58 kW) versus 160,000 BTU (47 kW).
How many CU3A boilers can be installed together?
The page markets multi-boiler installations up to 1592 MBH for the CU3A series, with no dedicated boiler pump required.
Questions about the Viessmann Vitocrossal 300 CU3A-199?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Viessmann Canada — Vitocrossal 300 CU3A product page · accessed September 8, 2026
- Service Instructions — Vitocrossal 300 CU3A, Canadian models 26, 35, 45, 57, 94, 125, 160, 199, doc 5673 649 - 20 · 5673 649 - 20 · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.