Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitogas 100 (GS1 / GS10)

Viessmann Vitogas 100 GS1-42

The Vitogas 100 GS1-42 is a five-section GS1 boiler: 165 MBH input (48 kW), 140 MBH output and 85.5% AFUE in the wide chassis.

DiscontinuedHistorically in Canada

Key figures

Max input
Max CSA output
AFUE
85.5 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitogas 100 GS1-42 in practice

The GS1-42 is rated 165 MBH (48 kW) input, 140 MBH (41 kW) output and 122 MBH (36 kW) Net I=B=R at 85.5% AFUE. It uses five cast-iron sections and six burners, weighing 428 lb (194 kg) with 4.2 USG of boiler water.

Dimensions remain the wide-chassis 864 x 840 mm (34 x 33 in) with a 845 mm overall height, and the boiler keeps the series' 60 psig maximum operating pressure. Like the rest of the GS1 range it is an atmospheric, chimney-vented design with a draft hood and vent damper.

Best suited to

  • Existing GS1-42 installations needing printed ratings
  • Loads between the GS1-35 and GS1-48
  • Documentation for five-section GS1 builds

Applicability and support

Model number
GS1-42
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitogas 100 GS1-42 specifications
SpecificationValueNote
Input
CSA input (natural gas)165 MBH48 kW, per the technical data manual
Output
CSA output / DOE heating capacity140 MBH41 kW
Net I=B=R rating122 MBH36 kW; based on piping and pick-up allowance of 1.15.
Efficiency
Efficiency (AFUE)85.5 %With intermittent pilot electronic ignition and vent damper.
Venting and air
Vent pipe collarPer model5 to 7 in. outside diameter per the technical data manual.
Physical and connections
Weight (boiler with insulation, burner and control)428 lb194 kg
Overall length864 mmPrinted as 34 in; heights 33¼ in (845 mm) with control in operating position.
Overall width840 mmPrinted as 33 in
Overall height (operation)845 mm33¼ in; 955 mm with control in operation position, 1180 mm for servicing.
Operating limits and other
FuelNatural gas or propane5 in. w.c. minimum NG supply pressure; 11 in. w.c. for propane.
Cast iron sections56 burners.
Boiler water content4.2 USG
Maximum operating pressure60 psig
Boiler supply / return1½ in. male threadGas supply ½ in. NPT.

Frequently asked questions

What is the GS1-42 rated at?

165 MBH (48 kW) input, 140 MBH (41 kW) output, a 122 MBH (36 kW) Net I=B=R rating and 85.5% AFUE.

How many sections does the GS1-42 have?

Five intermediate cast-iron sections with six burners, per the Vitogas 100 GS1 technical data manual.

What is the maximum operating pressure of the GS1-42?

60 psig, the same as every GS1 size; boiler water content is 4.2 USG.

Questions about the Viessmann Vitogas 100 GS1-42?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate