Weil-McLain · CGi (cast iron)

Weil-McLain CGi-7

The CGi-7 is the second-largest CGi Series 5 size of the cast iron line discontinued in Canada in 2023: 190 MBH CSA input, 162 MBH DOE heating capacity and a 141 MBH net AHRI rating at 84% AFUE.

DiscontinuedHistorically in Canada

Key figures

Max input
190 MBH
Max CSA output
162 MBH
AFUE
84 %
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Weil-McLain CGi-7 in practice

The CGi-7 reaches 190 MBH CSA input for 162 MBH of DOE heating capacity and a 141 MBH net AHRI rating at 84% AFUE, with the 3" vent connection stepping to 6" natural-draft venting on the US Series 5 page. It belongs to the US-current generation of Weil-McLain's cast iron gas-fired water boiler, which the Series 5 page builds around cast iron sections, an insulated steel jacket, natural draft and direct exhaust capability, a built-in low water cut-off and intermittent electronic ignition.

The CGi line is historical in Canada: Weil-McLain Canada's April 27, 2023 news release set a June 30, 2023 production cut-off under federal efficiency standards, with 20+ years of parts support promised and sales limited to remaining stock. weil-mclain.ca's discontinued page data covers the Series-3-era Canadian units (inputs 50-233 MBH, up to 85.1% AFUE, Cat. 1 B-vent or Cat. 3 AL29-4C venting); the Series 5 CGi-7 documented here is part of the US-current 48-222 MBH model set.

Best suited to

  • Large homes and light-commercial loads near 190 MBH with chimney or sidewall venting
  • Contractors mapping the CGi Series 5 range against Canadian-era units
  • Replacement documentation for larger cast iron CGi boilers

Applicability and support

Model number
CGi-7
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.

Weil-McLain CGi-7 specifications
SpecificationValueNote
Input
Input, maximum190 MBHCSA input per the US Series 5 product page.
Output
DOE heating capacity162 MBHDOE heating capacity per the US Series 5 product page.
Net AHRI water rating141 MBHNet AHRI water rating per the US Series 5 product page.
Efficiency
Efficiency (AFUE)84 %84% AFUE per the US Series 5 page; the CA discontinued page lists up to 85.1% for the Series-3-era Canadian units.
Venting and air
VentingCategory I B-vent (chimney) or Category III AL29-4C stainless steel (sidewall)Per the CA discontinued page, which notes Category I vent sizes increase from 3" to 4" up to the CGi-3 size and 3" to 5" on larger sizes; the US Series 5 page lists a 3" vent connection with 6" natural-draft venting for the CGi-7.
Operating limits and other
FuelNatural gas or propanePropane requires a conversion kit per the CA product page.

Frequently asked questions

What are the CGi-7's ratings?

190 MBH CSA input, 162 MBH DOE heating capacity, a 141 MBH net AHRI rating and 84% AFUE per the US Series 5 product page.

Was the CGi-7 sold in Canada?

Canada's discontinued-page data describes the Series-3-era CGi units at 50-233 MBH inputs; the Series 5 model set documented here is the generation Weil-McLain sells in the US.

What venting does the CGi-7 need?

It can vent to a chimney (Category I, B-vent) or a sidewall (Category III, AL29-4C stainless); the US Series 5 page lists a 3" vent connection with 6" natural-draft venting for this size.

Questions about the Weil-McLain CGi-7?