Weil-McLain · Series

Weil-McLain CGi (cast iron)

The CGi is Weil-McLain's cast iron induced-draft boiler, discontinued in Canada alongside the CGa by the June 30, 2023 production cut-off; the Canadian line-up (50-233 MBH) was the Series-3-era generation while the US moved on to CGi Series 5.

discontinuedhistoricalNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
85.1% AFUE
Fuel
Natural gas or propane; the CA product page lists propane with a conversion kit needed.
Venting
Category I B-vent for chimney or Category III AL29-4C stainless for sidewall, per the CA discontinued page; for Category I, vent size increases from 3" to 4" up to the CGi-3 and 3" to 5" on larger sizes.
Models documented
7
Warranty
Not verified

CA page: up to 85.1% AFUE for the Series-3-era Canadian units; the US CGi Series 5 manual lists 84.0% AFUE for its newer model set.

About the CGi (cast iron)

The CGi is the induced-draft companion to the CGa: a cast iron boiler the CA page lists at up to 85.1% AFUE with chimney or sidewall venting — Category I with B-vent or Category III with AL29-4C stainless steel pipe. Canada sold seven sizes from 50 to 233 MBH, with the CA page noting that Category I venting needs a jump from 3" to 4" up to the CGi-3 size and 3" to 5" on the rest.

Like the CGa, the CGi carries the CA phase-out note and is covered by the April 27, 2023 news release: production of mid-efficiency CGi and CGa hot water boilers ended on June 30, 2023 under the federal efficiency standard for non-condensing residential boilers under 300,000 BTUH, with 20+ years of parts support promised.

Generation separation matters here too. The Canadian CGi data reflects the older Series-3-era units, while the US CGi is now in Series 5 (manual 550-100-629/0126, January 2026, induced draft, 48-222 MBH inputs, 84.0% AFUE). The two countries therefore never shared a CGi generation after the 2023 cut-off, and owners should read codes and parts lists from the manual for their own unit's generation.

Highlights

  • Cast iron induced-draft boiler; Canada's CGi was Series-3 era
  • Seven Canadian sizes, 50-233 MBH, up to 85.1% AFUE
  • Chimney (Cat I B-vent) or sidewall (Cat III AL29-4C) venting
  • Production cut-off June 30, 2023 (CA news release, Apr 27 2023)
  • Parts availability promised for at least 20+ years
  • US currently sells the newer CGi Series 5 generation

Models

CGi (cast iron) models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedHistorically in Canada
Input
Output (max)
41 MBH
AFUE
84 %

The CGi-25 is the smallest CGi Series 5 size, from the cast iron line Canada discontinued in 2023: 48 MBH CSA input, 41 MBH DOE heating capacity and a 36 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
Output (max)
49 MBH
AFUE
84 %

The CGi-3 is the second-smallest CGi Series 5 size of the cast iron line Canada discontinued in 2023: 58 MBH CSA input, 49 MBH DOE heating capacity and a 43 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
Output (max)
77 MBH
AFUE
84 %

The CGi-4 is the mid-size CGi Series 5 model of the cast iron line discontinued in Canada in 2023: 90 MBH CSA input, 77 MBH DOE heating capacity and a 67 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
Output (max)
102 MBH
AFUE
84 %

The CGi-5 is the first of the larger CGi Series 5 sizes, from the cast iron line Canada discontinued in 2023: 119 MBH CSA input, 102 MBH DOE heating capacity and an 89 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
Output (max)
135 MBH
AFUE
84 %

The CGi-6 steps the CGi Series 5 line to 158 MBH CSA input with 135 MBH of DOE heating capacity — an 84% AFUE cast iron boiler from the line Canada discontinued in 2023.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
Output (max)
162 MBH
AFUE
84 %

The CGi-7 is the second-largest CGi Series 5 size of the cast iron line discontinued in Canada in 2023: 190 MBH CSA input, 162 MBH DOE heating capacity and a 141 MBH net AHRI rating at 84% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
Output (max)
189 MBH
AFUE
84 %

The CGi-8 tops the CGi Series 5 range at 222 MBH CSA input with 189 MBH of DOE heating capacity — the largest of the cast iron line Canada discontinued in 2023, rated 84% AFUE.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Weil-McLain CGi-25 and Weil-McLain CGi-3 and Weil-McLain CGi-4 and Weil-McLain CGi-5 and Weil-McLain CGi-6 and Weil-McLain CGi-7 and Weil-McLain CGi-8
SpecificationWeil-McLain CGi-25Weil-McLain CGi-3Weil-McLain CGi-4Weil-McLain CGi-5Weil-McLain CGi-6Weil-McLain CGi-7Weil-McLain CGi-8
input-min
Input, maximum48 MBH58 MBH90 MBH119 MBH158 MBH190 MBH222 MBH
DOE heating capacity41 MBH49 MBH77 MBH102 MBH135 MBH162 MBH189 MBH
Efficiency (AFUE)84 %84 %84 %84 %84 %84 %84 %
turndown
vent-max-3
vent-max-2
weight

Read the full comparison: Weil-McLain CGi-25 vs CGi-3

Read the full comparison: Weil-McLain CGi-3 vs CGi-4

Read the full comparison: Weil-McLain CGi-4 vs CGi-5

Read the full comparison: Weil-McLain CGi-5 vs CGi-6

Error codes and alerts

CGi (cast iron) alerts

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the CGi still sold in Canada?

No. Weil-McLain Canada phased out the CGi with a production cut-off of June 30, 2023 under federal efficiency standards, per its April 27, 2023 news release; remaining stock was available only while supplies lasted.

What venting does the CGi use?

The CA discontinued page lists chimney venting (Category I, B-vent) or sidewall venting (Category III, AL29-4C stainless), and notes Category I vent sizes increase from 3" to 4" up to the CGi-3 and 3" to 5" on larger sizes.

How does the Canadian CGi differ from the US model?

Canada's CGi was the Series-3-era generation (50-233 MBH, up to 85.1% AFUE) frozen at the 2023 cut-off, while the US sells CGi Series 5 (48-222 MBH, 84.0% AFUE, manual 550-100-629/0126). Read codes against the unit's own generation manual.