Weil-McLain · Ultra

Weil-McLain Ultra 399

The Ultra 399 is the largest Series 4 Ultra: 399 MBH input from an 80 MBH low fire, with the US table's asterisked 91.7% combustion efficiency and 364 MBH gross output — the manual's footnote says those figures are not an AFUE.

CurrentSold in Canada

Key figures

Max input
399 MBH
Max CSA output
364 MBH
AFUE
Min input
80 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Weil-McLain Ultra 399 in practice

The Ultra 399 tops the Series 4 line at 399 MBH maximum CSA input from an 80 MBH low fire, delivering a 317 MBH net AHRI rating. Its US spec table and brochure print 91.7% and 364 MBH with asterisks and the footnote "Combustion efficiency and gross output (not an AFUE)", so the 399 carries no DOE AFUE figure of its own — the CA page's "up to 94.1%" applies to the 230, not the 399.

The 399 shares the large Ultra cabinet with the 299: 4" venting only to 100 ft, 1-1/4" NPT supply and return tappings, a 3/4" NPT gas connection, 2.1 gallons of water content and a 297 lb shipping weight. It is heating-only and floor- or wall-mountable, with no altitude modification to 5,500 ft.

Best suited to

  • The largest residential loads and light-commercial plants near 400 MBH
  • Cascade Ultra systems anchored by 399 MBH units
  • Projects sized for 4" venting and 1-1/4" piping

Applicability and support

Model number
ULTRA-399
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.

Weil-McLain Ultra 399 specifications
SpecificationValueNote
Input
Input, maximum399 MBHCSA input (maximum).
Input, minimum80 MBHLow fire (80 MBH) per the Series 4 brochure's CSA input minimum column.
Output
DOE heating capacity364 MBHAsterisked gross output per the US table and brochure — not a DOE heating capacity figure.
Net AHRI water rating317 MBHNet AHRI rating per the boiler manual ratings table.
Efficiency
Combustion efficiency91.7 %Asterisked 91.7% combustion efficiency per the US table and brochure — NOT an AFUE; the CA page lists "up to 94.1%" which is the 230's rating, not this model's.
Domestic hot water
Domestic hot waterHeating-only boiler; domestic hot water via an indirect tank or separate appliance
Venting and air
Venting4" PVC, CPVC, polypropylene or stainless steel (Category IV); 4" pipe only on the 399Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit.
Max. equivalent vent/air length100 ft in 4"
Physical and connections
Weight297 lbApprox. shipping weight per the brochure.
Gas connection3/4" NPT
Heating water connections1-1/4" NPTSupply and return tappings 1-1/4"; minimum recommended pipe 1-1/2".
Operating limits and other
Turndown5:15:1 modulation (20-100% firing rate) per the brochure and CA page.
Boiler water content2.1 gal
Altitude rating5,500 ftNo modifications from sea level to 5,500 ft; the control has a high-altitude selection above 5,500 ft.
FuelNatural gas or propanePropane requires a conversion kit per the CA product page.

Frequently asked questions

Is the Ultra 399 rated 91.7% AFUE?

No. The US Series 4 table asterisks the 399's 91.7% figure as combustion efficiency with 364 MBH gross output — not an AFUE. Series 4 AFUE ratings run 93.5% to 94.1% on the 80 through 230.

What are the Ultra 399's ratings?

399 MBH input, 317 MBH net AHRI, 364 MBH gross output and 91.7% combustion efficiency per the asterisked US Series 4 table.

What venting does the Ultra 399 need?

4" pipe only, to 100 ft, with 1-1/4" NPT supply and return tappings and a 3/4" NPT gas connection.

Questions about the Weil-McLain Ultra 399?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.