Crown Aruba 4 AWR140E vs AWR175E

Verdict in brief

The AWR140E and AWR175E are the mid-to-large legacy Aruba 4 sizes, both NON-condensing Category I cast-iron boilers at 83.6%/83.5% AFUE: the 175E fires a fixed 175 MBH against 140 MBH (DOE 146 vs 117 MBH, net AHRI 127 vs 102 MBH) over 6 sections, growing dimension A from 18-1/2" to 21-1/2" and the flue connector from 6" to 7".

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Crown Aruba 4 AWR140E and Crown Aruba 4 AWR175E
SpecificationCrown Aruba 4 AWR140ECrown Aruba 4 AWR175E
Input140 MBH175 MBH
DOE heating capacity117 MBH146 MBH
Net AHRI water rating102 MBH127 MBH
Efficiency (AFUE)83.6 %83.5 %
Cast-iron sections56
Dimensions (A × B)18-1/2" × 31-1/2"21-1/2" × 31-3/4"
VentingCategory I natural draft — draft hood built into the boiler; lined masonry or listed metal chimneyCategory I natural draft — draft hood built into the boiler; lined masonry or listed metal chimney
Supply/return tappings1-1/4"1-1/4"
Ignition and controlsHoneywell S9361A interrupted ignition with vent damperHoneywell S9361A interrupted ignition with vent damper
FuelNatural gas or propaneNatural gas or propane
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both are cast-iron, NON-condensing, Category I natural-draft Aruba 4 boilers with built-in draft hoods, mandatory vent dampers, 1-1/4" side-relocatable tappings and Honeywell S9361A interrupted ignition with EnviraCOM options — differing in capacity and physical size only.

The AWR175E adds 35 MBH of fixed input (175 vs 140) across 6 cast-iron sections (5 on the 140E), printing 146 MBH DOE heating capacity and a 127 MBH net AHRI water rating against 117 and 102 MBH, at 83.5% AFUE versus 83.6%.

Physically the 175E grows dimension A from 18-1/2" to 21-1/2" and steps the flue connector (C) from 6" to 7", with dimension B moving from 31-1/2" to 31-3/4". Above 2,000 ft both require different main burner orifices; NG/LP suffix codes complete the model numbers (AWR140EN/EL, AWR175EN/EL).

Crown Boiler Co.

Crown Aruba 4 AWR140E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.6 %

The Crown Aruba 4 AWR140E fires a fixed 140 MBH for 117 MBH DOE heating capacity and a 102 MBH net AHRI rating at 83.6% AFUE across 5 cast-iron sections, stepping to a 6" flue connector.

Natural gasPropaneHeating-only

Crown Boiler Co.

Crown Aruba 4 AWR175E

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
83.5 %

The Crown Aruba 4 AWR175E fires a fixed 175 MBH for 146 MBH DOE heating capacity and a 127 MBH net AHRI rating at 83.5% AFUE across 6 cast-iron sections, with a 7" flue connector.

Natural gasPropaneHeating-only

Frequently asked questions

What does the AWR175E add over the AWR140E?

35 MBH of fixed input, 29 MBH of DOE capacity (146 vs 117), 25 MBH of net AHRI (127 vs 102), one more section, a 7" flue connector against 6", and dimension A of 21-1/2" against 18-1/2".

Which of the two is more efficient?

They are nearly level: 83.6% AFUE on the AWR140E against 83.5% on the AWR175E per the ratings table.

Can either run on propane?

Yes — with the L suffix (AWR140EL / AWR175EL); both need different main burner orifices above 2,000 ft.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate