Crown Boiler Co. · Aruba 4

Crown Aruba 4 AWR175E

The Crown Aruba 4 AWR175E fires a fixed 175 MBH for 146 MBH DOE heating capacity and a 127 MBH net AHRI rating at 83.5% AFUE across 6 cast-iron sections, with a 7" flue connector.

DiscontinuedCanadian status unknown

Key figures

Max input
175 MBH
Max CSA output
AFUE
83.5 %
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Aruba 4 AWR175E in practice

The AWR175E is the first of the large Aruba 4 sizes: a fixed 175 MBH input for 146 MBH DOE heating capacity and a 127 MBH net AHRI water rating at 83.5% AFUE, over 6 cast-iron sections (Table 2.2, manual P/N 9902339, May 2018). It is a NON-condensing, Category I natural-draft boiler with the draft hood built in, mandatory vent damper, and a 7" flue connector (C) into a lined masonry or listed metal chimney.

Supply/return tappings are 1-1/4" (side-relocatable) with the gas connection per the manifold and a required sediment trap; Honeywell S9361A interrupted ignition with EnviraCOM options listed. Dimension A is 21-1/2" with dimension B 31-3/4" per the ratings table. Above 2,000 ft different main burner orifices apply; NG/LP suffix codes (AWR175EN / AWR175EL) complete the model.

Aruba 4 is legacy (current line: Aruba 6, AWR038C–AWR280C) with productStatus 'discontinued'; canadianStatus stays 'unknown'. A licensed contractor performs installation, gas and venting work.

Best suited to

  • Large homes with a chimney-vented fixed 175 MBH AWR load
  • Owners researching the large end of the legacy Aruba 4 cast-iron line
  • Projects matching a 7" flue connector into an existing chimney

Applicability and support

Model number
AWR175E
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Aruba 4 AWR175E specifications
SpecificationValueNote
Input
Input175 MBHFixed input (no modulation) per the AWR space-heating ratings table (Table 2.2); NG/LP suffix added to the model (e.g. AWR210EN / AWR210EL).
Output
DOE heating capacity146 MBHHeating capacity per the AWR ratings table (Table 2.2).
Net AHRI water rating127 MBHNet AHRI water rating based on a piping and pickup allowance of 1.15 per the ratings table.
Efficiency
Efficiency (AFUE)83.5 %AFUE per the AWR ratings table (Table 2.2).
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingCategory I natural draft — draft hood built into the boiler; lined masonry or listed metal chimneyVent damper installation is mandatory on all AWR boilers; flue connector size (C) 7" per the ratings table. Boilers above 2,000 ft need different main burner orifices.
Physical and connections
Cast-iron sections6Number of sections per the AWR ratings table.
Dimensions (A × B)21-1/2" × 31-3/4"Dimension A and dimension B per the AWR ratings table (Table 2.2); flue connector (C) is 7".
Supply/return tappings1-1/4"Supply and return tappings 1-1/4" (side-relocatable) per the installation manual.
Operating limits and other
Ignition and controlsHoneywell S9361A interrupted ignition with vent damperEnviraCOM options listed in the installation manual; the control shows discrete Err codes.
FuelNatural gas or propaneAdd suffix N for natural gas or L for propane to the basic boiler model (e.g. AWR210EN, AWR210EL).

Frequently asked questions

What are the AWR175E's ratings?

175 MBH fixed input, 146 MBH DOE heating capacity, a 127 MBH net AHRI water rating and 83.5% AFUE per the AWR ratings table.

How does the AWR175E differ from the AWR140E?

Input rises from 140 to 175 MBH, sections from 5 to 6, DOE capacity from 117 to 146 MBH and net AHRI from 102 to 127 MBH; the flue connector (C) grows from 6" to 7" and dimension B from 31-1/2" to 31-3/4".

Does the AWR175E have a vent damper?

Yes — vent damper installation is mandatory on all AWR boilers per the installation manual.

Questions about the Crown Aruba 4 AWR175E?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate