Slant/Fin CHS-110 vs CHS-154

Verdict in brief

The CHS-110 and CHS-154 are adjacent sizes in Slant/Fin's CHS high-efficiency fire-tube condensing gas boiler line. The CHS-154 fires up to 154 MBH against the CHS-110's 108 MBH, printing 141 MBH heating capacity (99) and a 123 MBH AHRI net rating (86); both 95%. both use 1" NPT water connections, both use ½" NPT gas and both use 3" vent/air connections. Turndown is printed as 5:1 on the CHS-110 and not printed on the CHS-154.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Slant/Fin CHS-110 and Slant/Fin CHS-154
SpecificationSlant/Fin CHS-110Slant/Fin CHS-154
Input, minimum21.6 MBH15.4 MBH
Input, maximum108 MBH154 MBH
Heating capacity99 MBH141 MBH
Net AHRI rating86 MBH123 MBH
AFUE95 %95 %
Water connections1" NPT1" NPT
Gas connection½" NPT½" NPT
Vent / air connection3"3"

What actually separates them

Both models are CHS Series high-efficiency fire-tube condensing gas boilers held in Slant/Fin's active 'Boilers' library section, with direct spark ignition, a modulating burner, outdoor reset, DHW priority and lead-lag capability up to 8 boilers. Slant/Fin prints no 'current' or 'discontinued' sentence; section placement is the only official status wording.

The official submittal table prints 21.6–108 MBH input on the CHS-110 (LP 22.6–113), 99 MBH heating capacity and a 86 MBH AHRI net rating, against 15.4–154 MBH, 141 MBH heating capacity and 123 MBH on the CHS-154. Turndown is printed as 5:1 and not printed respectively.

Connections scale with the size: both use 1" NPT water connections, both use ½" NPT gas and both use 3" vent/air connections. The CHS hub also hosts the official 2018 recall documents (CPSC notice plus contractor and homeowner notifications) — owners should check whether their unit's date range is affected. A heat-loss calculation decides between the two sizes, and gas, venting and combustion work belongs with a licensed contractor.

Status unknownCanadian status unknown
Input
21.6–108 MBH
Output (max)
—
AFUE
95 %

The Slant/Fin CHS-110 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 21.6–108 MBH input (NG; LP 22.6–113), 99 MBH heating capacity, a 86 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
15.4–154 MBH
Output (max)
—
AFUE
95 %

The Slant/Fin CHS-154 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 15.4–154 MBH input, 141 MBH heating capacity, a 123 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only

Frequently asked questions

What does the CHS-154 add over the CHS-110?

154 MBH maximum input against 108 MBH, 141 MBH heating capacity against 99 MBH, and a 123 MBH AHRI net rating against 86 MBH, per the official CHS submittal sheet.

Are both boilers condensing?

Yes — every CHS is a high-efficiency fire-tube condensing gas boiler; the series prints 95.0% AFUE for CHS-85 through CHS-285 and 95.4% thermal efficiency for CHS-340/399.

Was the CHS recalled?

The official CHS hub hosts 2018 recall documents — a CPSC notice plus contractor and homeowner official notifications. Owners should open the current notices on slantfin.com and act on any that apply to their unit's date range.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate