Comparison

Slant/Fin CHS-154 vs CHS-175

Verdict in brief

The CHS-154 and CHS-175 are adjacent sizes in Slant/Fin's CHS high-efficiency fire-tube condensing gas boiler line. The CHS-175 fires up to 175 MBH against the CHS-154's 154 MBH, printing 163 MBH heating capacity (141) and a 142 MBH AHRI net rating (123); both 95%. water connections step from 1" NPT to 1¼" NPT, both use ½" NPT gas and both use 3" vent/air connections. Turndown is printed as not printed on the CHS-154 and 5.6:1 on the CHS-175.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Slant/Fin CHS-154 and Slant/Fin CHS-175
SpecificationSlant/Fin CHS-154Slant/Fin CHS-175
Input, minimum15.4 MBH31 MBH
Input, maximum154 MBH175 MBH
Heating capacity141 MBH163 MBH
Net AHRI rating123 MBH142 MBH
AFUE95 %95 %
Water connections1" NPT1¼" NPT
Gas connection½" NPT½" NPT
Vent / air connection3"3"

What actually separates them

Both models are CHS Series high-efficiency fire-tube condensing gas boilers held in Slant/Fin's active 'Boilers' library section, with direct spark ignition, a modulating burner, outdoor reset, DHW priority and lead-lag capability up to 8 boilers. Slant/Fin prints no 'current' or 'discontinued' sentence; section placement is the only official status wording.

The official submittal table prints 15.4–154 MBH input on the CHS-154, 141 MBH heating capacity and a 123 MBH AHRI net rating, against 31–175 MBH, 163 MBH heating capacity and 142 MBH on the CHS-175. Turndown is printed as not printed and 5.6:1 respectively.

Connections scale with the size: water connections step from 1" NPT to 1¼" NPT, both use ½" NPT gas and both use 3" vent/air connections. The CHS hub also hosts the official 2018 recall documents (CPSC notice plus contractor and homeowner notifications) — owners should check whether their unit's date range is affected. A heat-loss calculation decides between the two sizes, and gas, venting and combustion work belongs with a licensed contractor.

Status unknownCanadian status unknown
Input
15.4–154 MBH
Output (max)
AFUE
95 %

The Slant/Fin CHS-154 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 15.4–154 MBH input, 141 MBH heating capacity, a 123 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
31–175 MBH
Output (max)
AFUE
95 %

The Slant/Fin CHS-175 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 31–175 MBH input, 163 MBH heating capacity, a 142 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only

Frequently asked questions

What does the CHS-175 add over the CHS-154?

175 MBH maximum input against 154 MBH, 163 MBH heating capacity against 141 MBH, and a 142 MBH AHRI net rating against 123 MBH, per the official CHS submittal sheet.

Are both boilers condensing?

Yes — every CHS is a high-efficiency fire-tube condensing gas boiler; the series prints 95.0% AFUE for CHS-85 through CHS-285 and 95.4% thermal efficiency for CHS-340/399.

Was the CHS recalled?

The official CHS hub hosts 2018 recall documents — a CPSC notice plus contractor and homeowner official notifications. Owners should open the current notices on slantfin.com and act on any that apply to their unit's date range.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate