Slant/Fin CHS-201 vs CHS-285

Verdict in brief

The CHS-201 and CHS-285 are adjacent sizes in Slant/Fin's CHS high-efficiency fire-tube condensing gas boiler line. The CHS-285 fires up to 285 MBH against the CHS-201's 200 MBH, printing 263 MBH heating capacity (185) and a 229 MBH AHRI net rating (161); both 95%. both use 1¼" NPT water connections, gas steps from ½" NPT to ¾" NPT and both use 3" vent/air connections. Turndown is printed as 10:1 on the CHS-201 and 10:1 on the CHS-285.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Slant/Fin CHS-201 and Slant/Fin CHS-285
SpecificationSlant/Fin CHS-201Slant/Fin CHS-285
Input, minimum20 MBH28.5 MBH
Input, maximum200 MBH285 MBH
Heating capacity185 MBH263 MBH
Net AHRI rating161 MBH229 MBH
AFUE95 %95 %
Water connections1¼" NPT1¼" NPT
Gas connection½" NPT¾" NPT
Vent / air connection3"3"

What actually separates them

Both models are CHS Series high-efficiency fire-tube condensing gas boilers held in Slant/Fin's active 'Boilers' library section, with direct spark ignition, a modulating burner, outdoor reset, DHW priority and lead-lag capability up to 8 boilers. Slant/Fin prints no 'current' or 'discontinued' sentence; section placement is the only official status wording.

The official submittal table prints 20–200 MBH input on the CHS-201, 185 MBH heating capacity and a 161 MBH AHRI net rating, against 28.5–285 MBH, 263 MBH heating capacity and 229 MBH on the CHS-285. Turndown is printed as 10:1 and 10:1 respectively.

Connections scale with the size: both use 1¼" NPT water connections, gas steps from ½" NPT to ¾" NPT and both use 3" vent/air connections. The CHS hub also hosts the official 2018 recall documents (CPSC notice plus contractor and homeowner notifications) — owners should check whether their unit's date range is affected. A heat-loss calculation decides between the two sizes, and gas, venting and combustion work belongs with a licensed contractor.

Status unknownCanadian status unknown
Input
20–200 MBH
Output (max)
—
AFUE
95 %

The Slant/Fin CHS-201 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 20–200 MBH input, 185 MBH heating capacity, a 161 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
28.5–285 MBH
Output (max)
—
AFUE
95 %

The Slant/Fin CHS-285 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 28.5–285 MBH input, 263 MBH heating capacity, a 229 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Natural gasPropaneHeating-only

Frequently asked questions

What does the CHS-285 add over the CHS-201?

285 MBH maximum input against 200 MBH, 263 MBH heating capacity against 185 MBH, and a 229 MBH AHRI net rating against 161 MBH, per the official CHS submittal sheet.

Are both boilers condensing?

Yes — every CHS is a high-efficiency fire-tube condensing gas boiler; the series prints 95.0% AFUE for CHS-85 through CHS-285 and 95.4% thermal efficiency for CHS-340/399.

Was the CHS recalled?

The official CHS hub hosts 2018 recall documents — a CPSC notice plus contractor and homeowner official notifications. Owners should open the current notices on slantfin.com and act on any that apply to their unit's date range.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate