Skip to content
Boilers.caby ROMA Heating & Cooling

Slant/Fin · CHS Series (CHS-85 to CHS-399)

Slant/Fin CHS-201

The Slant/Fin CHS-201 is a size in the line of the CHS high-efficiency fire-tube condensing gas boiler series: 20–200 MBH input, 185 MBH heating capacity, a 161 MBH AHRI net rating and 95% AFUE. The CHS hub sits in Slant/Fin's active 'Boilers' library section and also hosts the official 2018 recall notices.

Status unknownCanadian status unknown

Key figures

Max input
200 MBH
Max CSA output
AFUE
95 %
Min input
20 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Slant/Fin CHS-201 in practice

The CHS-201 is a size in the line of Slant/Fin's CHS Series, a high-efficiency fire-tube condensing gas boiler line held in the official library's active 'Boilers' section ('Boilers > CHS Series'). The official submittal ratings table (720) prints 20–200 MBH input for this size (a single min–max range is printed), 185 MBH heating capacity, a 161 MBH AHRI net rating and 95% AFUE. Turndown is printed as 10:1.

It is a condensing fire-tube design with direct spark ignition, a modulating burner, outdoor reset and DHW priority, and lead-lag capability up to 8 boilers. Water connections are 1¼" NPT, gas is ½" NPT and the vent/air connection is 3". The boiler is wall-standard with a floor kit option, carries MAWP of 30 psi (80 psi on CHS-175 and up), and the line's weights run 110–250 lb with water per the official submittal data.

Slant/Fin prints no 'current' or 'discontinued' sentence; the hub's active 'Boilers' placement is the only official status signal, so Boilers.ca describes the series as current library / documents available on slantfin.com without asserting current production. IMPORTANT: the CHS hub also hosts the official 2018 recall documents — a CPSC notice plus contractor and homeowner notifications — and owners should confirm whether their unit's date range is affected. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; gas, venting and combustion work belongs with a licensed contractor.

Best suited to

  • Residential hydronic systems whose heat-loss calculation fits 185 MBH of heating capacity
  • Wall-hung installs (floor kit available) needing a modulating condensing boiler
  • Owners of an installed CHS checking ratings and the official 2018 recall notices

Applicability and support

Model number
CHS-201
Canadian availability
unknown
Production status
unknown
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Slant/Fin. Units are shown with every value; notes flag conflicting sources or missing figures.

Slant/Fin CHS-201 specifications
SpecificationValueNote
Input
Input, minimum20 MBHMinimum input in MBH as printed in the official submittal ratings table (a single min–max range is printed for this size).
Input, maximum200 MBHMaximum input in MBH as printed in the official submittal ratings table (a single min–max range is printed for this size).
Output
Heating capacity185 MBHHeating capacity in MBH as printed in the official submittal ratings table.
Net AHRI rating161 MBHAHRI net rating in MBH as printed in the official submittal ratings table.
Efficiency
AFUE95 %95.0% AFUE as printed in the official submittal ratings table.
Domestic hot water
Domestic hot waterHeating-only boiler — DHW priority control; domestic hot water comes from a separate indirect tankThe CHS is a heating boiler; the submittal data prints DHW priority in the control features.
Venting and air
Vent / air connection3"Vent/air connection size as printed in the official submittal data (3" on CHS-85 through CHS-285; 4" on CHS-340/399).
Physical and connections
Weight with water110–250 lb (line range)The official submittal data prints the line range (110–250 lb with water) rather than per-size weights.
MountingWall standard; floor kit availablePer the official submittal data.
Maximum allowable working pressure30 psi (80 psi on CHS-175 and up)MAWP as printed in the official submittal data.
Operating limits and other
Water connections1¼" NPTWater connection size as printed in the official submittal data (1" on CHS-85/110/154; 1¼" on CHS-175/201/285; 1½" on CHS-340/399).
Gas connection½" NPTGas connection size as printed in the official submittal data (½" NPT on CHS-85 through CHS-201; ¾" on CHS-285 through CHS-399).
Turndown10:1Turndown as printed in the official submittal data (10:1 on CHS-201/285/340/399; 5.6:1 on CHS-175; 5:1 on CHS-85/110).
Ignition / burnerDirect spark ignition with a modulating burnerOutdoor reset, DHW priority and lead-lag up to 8 boilers are printed in the official submittal data.

Frequently asked questions

What are the CHS-201's ratings?

20–200 MBH input, 185 MBH heating capacity, a 161 MBH AHRI net rating and 95% AFUE, per the official CHS submittal sheet.

Is the CHS-201 a condensing boiler?

Yes — the CHS Series is a high-efficiency fire-tube condensing gas boiler line, with 3" vent/air connections on CHS-85 through CHS-285 and 4" on CHS-340/399.

Was the CHS recalled?

The official CHS hub hosts 2018 recall documents — a CPSC notice plus contractor and homeowner official notifications. Owners should open the current notices on slantfin.com and act on any that apply to their unit's date range.

Questions about the Slant/Fin CHS-201?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.