Crown Phantom II PHTM2180H vs HTP UFT-199W

Verdict in brief

The Crown Phantom II PHTM2180H and HTP UFT-199W are both wall-hung, heating-only condensing boilers with 10:1 turndown claims, but their ratings differ: Crown publishes 20 to 180 MBH input at 95.0% AFUE in a 132 lb unit, while HTP publishes 19.9 to 199 MBH at 96% AFUE in a 110 lb unit. Efficiency, capacity and electrical draw differ; a heat-loss calculation decides which one the home can use.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Crown Phantom II PHTM2180H and HTP UFT-199W
SpecificationCrown Phantom II PHTM2180HHTP UFT-199W
Input, minimum20 MBH19.9 MBH
Input, maximum180 MBH199 MBH
Efficiency (AFUE)95 %96 %
Turndown ratio10:110:1
Shipping weight132 lb110 lb
Dimensions (D × W × H)20.4" × 17.8" × 29.8"19.7" x 37" x 16.8"
Electrical120 VAC, 60 Hz, 1-phase, 1.8 A120 V / 60 Hz, 6 A, maximum power consumption 160 W
FuelNatural gas or LPNatural gas or propane

What actually separates them

Both are heating-only wall-hung condensing boilers on natural gas or LP, and both publish 10:1 turndown claims, but the headline numbers point different ways. Crown lists the Phantom II PHTM2180H at 20 to 180 MBH input with a 95.0% AFUE and a 169 MBH DOE heating capacity, while HTP lists the UFT-199W at 19.9 to 199 MBH with a 96% DOE AFUE and 189 MBH heating capacity — the HTP both fires higher and carries the higher published efficiency.

Physical and electrical details reinforce the HTP's small package: the UFT-199W weighs 110 lb and measures 19.7 by 37 by 16.8 inches with a 120 V / 60 Hz draw of 6 A (maximum power consumption 160 W), while the Phantom II PHTM2180H weighs 132 lb at 20.4 by 17.8 by 29.8 inches and draws 1.8 A on 120 VAC. The Crown's lower amperage and shorter cabinet can suit tighter electrical panels or low ceilings.

Both makers document venting in their own terms: Crown allows 2" to 70 feet or 3" to 135 feet with deratings noted at maximum length, while HTP publishes 2" to 50 feet or 3" to 100 feet combined equivalent feet for the UFT. Both are heating-only units needing an indirect tank for hot water, and both should be selected from a heat-loss calculation rather than the AFUE sticker alone.

CurrentCanadian status unknown
Input
20–180 MBH
Output (max)
—
AFUE
95 %

The Crown Phantom II PHTM2180H is the largest Phantom II heat-only boiler: 20 to 180 MBH input at 95.0% AFUE with 169 MBH DOE heating capacity and a 147 MBH net AHRI rating, in the same 132 lb large cabinet as the 2150H.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
19.9–199 MBH
Output (max)
—
AFUE
96 %

The HTP UFT-199W is the 199 MBH class wall-mounted model of HTP's Universal Fire Tube (UFT) medium-mass condensing boiler line: 19.9 to 199 MBH natural-gas input, 96% DOE AFUE and 189 MBH heating capacity in a 110 lb wall cabinet.

Natural gasPropaneHeating-only

Frequently asked questions

Which boiler carries the higher AFUE rating?

HTP publishes 96% DOE AFUE for the UFT-199W against Crown's 95.0% for the Phantom II PHTM2180H, though real savings depend on matching the boiler to the load.

How do the venting limits compare?

Crown allows 2" to 70 feet or 3" to 135 feet for the PHTM2180H, while HTP publishes 2" to 50 feet or 3" to 100 feet combined equivalent feet for the UFT-199W.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.