Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Dunkirk DCB-125 vs DCB-165

Verdict in brief

The DCB-165 is the largest DCB heating-only boiler (the heat-only line tops at 165 — the 205 class exists only as the DCC-205 combi). It steps input from 125 to 164 MBH maximum and heating capacity from 113 to 153 MBH (net water 133 against 98 MBH), but moves to the deep 21-1/2" cabinet at 125 lb with 1" system connections and 3/4" NPT condensate.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Dunkirk DCB-125 and Dunkirk DCB-165
SpecificationDunkirk DCB-125Dunkirk DCB-165
Central-heating input, minimum22 MBH29.5 MBH
Central-heating input, maximum125 MBH164 MBH
AFUE95 %95 %
Heating capacity113 MBH153 MBH
Net water rating98 MBH133 MBH
Turndown, heating mode5.7:15.5:1
Dimensions (H x W x D)30" x 17-3/4" x 13-9/16"30" x 17-3/4" x 21-1/2"
Weight104 lb125 lb

What actually separates them

Both are wall-hung, heating-only models of the DCC/DCB AI family at 95% AFUE. The DCB-125 uses the shallow 13-9/16" cabinet at 104 lb with 3/4" system supply/return (G straight thread) and 13/16" ID-hose condensate; the DCB-165 is the deep 21-1/2" cabinet at 125 lb with 1-1/4 gallons of water content, 1" system connections and 3/4" NPT condensate.

The sell sheet prints CH input of 22-125 MBH on the DCB-125 against 29.5-164 MBH on the DCB-165, with heating capacity of 113 versus 153 MBH and net water ratings of 98 versus 133 MBH.

The DCB-165's 29.5 MBH minimum fire is 7.5 MBH above the DCB-125's 22 MBH floor, so the larger boiler condenses less in mild weather — it earns its place only where the design-day load exceeds 113 MBH of capacity. Both pages print '(While supplies last)' with no current documents; guidance is for service and parts of installed units.

Dunkirk Boilers

Dunkirk DCB-125

DiscontinuedCanadian status unknown
Input
22–125 MBH
Output (max)
—
AFUE
95 %

The Dunkirk DCB-125 is the 125 MBH-class central-heating model of the DCB 'AI' condensing line: 22 to 125 MBH input at 95% AFUE with 113 MBH heating capacity and a 98 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk DCB-165

DiscontinuedCanadian status unknown
Input
29.5–164 MBH
Output (max)
—
AFUE
95 %

The Dunkirk DCB-165 is the 164 MBH-class central-heating model of the DCB 'AI' condensing line: 29.5 to 164 MBH input at 95% AFUE with 153 MBH heating capacity and a 133 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneHeating-only

Frequently asked questions

Is there a DCB-205?

No — the heat-only line tops at DCB-165 as printed. The 205 MBH-class unit is the DCC-205 combi.

Do the two models install the same?

No — the DCB-165 is the deep 21-1/2" cabinet at 125 lb with 1" system connections and 3/4" NPT condensate, versus the shallow 104 lb DCB-125 with 3/4" connections.

Which size suits a larger heat load?

The one the heat-loss calculation picks: beyond the DCB-125's 113 MBH of heating capacity the DCB-165 adds reach, but its 29.5 MBH minimum fire is a real cost in mild weather.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate