Skip to content
Boilers.caby ROMA Heating & Cooling

Dunkirk Boilers · DCC/DCB (AI condensing)

Dunkirk DCB-165

The Dunkirk DCB-165 is the 164 MBH-class central-heating model of the DCB 'AI' condensing line: 29.5 to 164 MBH input at 95% AFUE with 153 MBH heating capacity and a 133 MBH net water rating. The DCB page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

DiscontinuedCanadian status unknown

Key figures

Max input
164 MBH
Max CSA output
AFUE
95 %
Min input
29.5 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Dunkirk DCB-165 in practice

The DCB-165 is the 164 MBH-class central-heating model of Dunkirk's DCB line — the wall-hung 'AI' condensing platform the official page describes with AI control technology that automatically sets up the boiler during startup, recognizes natural or LP gas without a conversion kit, and continuously monitors combustion. The sell sheet prints 29.5 to 164 MBH central-heating input with 153 MBH heating capacity, a 133 MBH net water rating and 95% AFUE.

It is a wall-hung condensing design at 30" x 17-3/4" (21-1/2" deep) weighing 125 lb on the 316L stainless steel heat exchanger and burner, with System supply/return 1" G (straight thread), gas at 3/4" NPT and 3/4" NPT condensate, plus the LABOR SAVER manifold included (System supply/return with LABOR SAVER manifold 1-1/2" copper sweat).

Status as printed on September 9, 2026: the DCB page prints '(While supplies last)' under the product title with no current documents, so this model is recorded as discontinued (sell-through). The floor-standing DCBF version is documented at the same ratings on its own page. Gas work belongs with a licensed contractor against the archived Rev. A manual (PN 240013687).

Best suited to

  • Homes whose heat-loss calculation fits the 164 MBH-class heating-only boiler
  • Owners of an installed DCC/DCB unit identifying the model and pulling the archived documentation

Applicability and support

Model number
DCB-165
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Dunkirk Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

Dunkirk DCB-165 specifications
SpecificationValueNote
Input
Central-heating input, minimum29.5 MBHCH input minimum in MBH as printed in the official DCC/DCB sell sheet table.
Central-heating input, maximum164 MBHCH input maximum in MBH as printed in the official DCC/DCB sell sheet table.
Output
Heating capacity153 MBHHeating capacity in MBH as printed in the official DCC/DCB sell sheet table.
Net water rating133 MBHNet water rating in MBH (piping and pickup allowance of 1.15) as printed in the official DCC/DCB sell sheet table.
Efficiency
AFUE95 %95% AFUE as printed in the official DCC/DCB sell sheet table and on the product page.
Venting and air
VentingCoaxial polypropylene or 2-pipe polypropylene/CPVC/PVCCoaxial polypropylene 5"/3" or 2-pipe polypropylene 2" or 3", or 2-pipe CPVC/PVC 3", per the sell sheet (2-pipe requires an adapter sold separately).
Physical and connections
Dimensions (H x W x D)30" x 17-3/4" x 21-1/2"Dimensions per the official sell sheet; the 165/205-class sizes use the 21-1/2" depth.
Weight125 lbPer the official DCC/DCB sell sheet (94 lb on the 75/100 sizes, 103 lb on the 115/150 sizes, 104 lb on the 125, 125 lb on the 165/205 sizes).
Boiler water content1-1/4 galPer the official DCC/DCB sell sheet (1 gal on the 75-150 sizes, 1-1/4 gal on the 165/205 sizes).
Heat exchanger316L stainless steel heat exchanger and burnerAs printed on the official DCC product page: DCC-205, DCC-150 and DCC-115 are also equipped with a stainless steel brazed-plate heat exchanger.
Electrical
Power supply120 V ac, 60 Hz, 1 phase, less than 21 APer the official DCC/DCB sell sheet (15 A circuit recommended).
Operating limits and other
Turndown, heating mode5.5:1As printed on the official product page for this model.
ConnectionsSystem supply/return 1" G (straight thread); gas 3/4" NPT; condensate 3/4" NPTPer the official sell sheet connection table; with the LABOR SAVER manifold, system supply/return step up to System supply/return with LABOR SAVER manifold 1-1/2" copper sweat.
Gas typeNatural gas or LP — recognized automaticallyThe AI control recognizes natural or LP gas during startup; no conversion kit required, as printed on the page.

Frequently asked questions

Is the DCB-165 discontinued?

The official page prints '(While supplies last)' with an empty 'Current Documents' tab, which Boilers.ca records as discontinued (sell-through); the Rev. A manual set stays downloadable under 'Archived Documents'.

Is the DCB-165 a combi boiler?

No — DCB codes are central-heating only; Dunkirk's combi versions of this platform carry DCC codes.

Is DCC/DCB the same boiler as Utica's MAC/MAH?

Yes — both ECR International brands sell the same AI wall-hung platform and share the Rev. A boiler manual print PN 240013687 (MGC-2209-REV-A).

Questions about the Dunkirk DCB-165?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.