The EFT-285 is the first model of the 10:1 generation: it fires 28,500-285,000 BTU/hr to 262 MBH capacity, moves to a 1" NPTF gas inlet and an 80 PSI MAWP, and cuts the combined vent allowance to 3" (150 ft). The EFT-199 remains a 5:1 model at 39,800-199,000 BTU/hr with a 30 PSI MAWP and 3" (200 ft) venting.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EFT-199 and HTP EFT-285
SpecificationHTP EFT-199HTP EFT-285
Input rate, minimum39.8 MBH28.5 MBH
Input rate, maximum199 MBH285 MBH
Heating capacity183 MBH262 MBH
Shipping weight198 lb203 lb
Boiler water content6.1 gal6.1 gal
Dimensions (W x H x D)20" x 32.6" x 20.6"20" x 32.6" x 20.6"
CH supply/return connection1-1/4" copper SWT1-1/4" copper SWT
Venting3" (200 ft combined)3" (150 ft combined)
Turndown5:110:1

What actually separates them

The EFT-199 prints 39,800-199,000 BTU/hr with 183 MBH capacity in the 5:1 generation; the EFT-285 prints 28,500-285,000 with 262 MBH in the LP-657 10:1 generation (LP-387 prints the earlier 5:1 range of 57,000-285,000).

The EFT-285's gas inlet is 1" NPTF (from 3/4"), its MAWP/relief rises to 80 PSI (from 30) and its combined vent allowance is 3" (150 ft) rather than the 3" (200 ft) of the 55-199 models.

Weight moves from 198 to 203 lb and water content stays at about 6.1 gal; the EFT-285's higher efficiency print (95.1% AFUE) matches the retired page table.

DiscontinuedCanadian status unknown
Input
39.8–199 MBH
Output (max)
—
AFUE
—

The HTP EFT-199 is the 199 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 39,800 to 199,000 BTU/hr input, 183 MBH heating capacity, 198 lb shipping weight and a 5:1 turndown, recorded from the official LP-387 technical table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
28.5–285 MBH
Output (max)
—
AFUE
—

The HTP EFT-285 is the 285 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 28,500 to 285,000 BTU/hr input, 262 MBH heating capacity, 203 lb shipping weight and a 10:1 turndown, recorded from the official LP-387 technical table and the LP-657 10:1-generation table.

Natural gasPropaneHeating-only

Frequently asked questions

Why do the EFT-199 and EFT-285 have different turndowns?

The EFT-199 belongs to the 5:1 EFT-55-199 generation; the EFT-285 is a 10:1 model (manufactured on/after 10/30/17) per LP-657/LP-659.

What changes at the EFT-285 step?

Gas inlet to 1" NPTF, MAWP/relief to 80 PSI, vent allowance to 3" (150 ft) and capacity to 262 MBH.

Which manual covers the EFT-285?

LP-657 for the 10:1 generation, with LP-387 covering the full line's earlier table.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.