Boilers.caby ROMA Heating & Cooling

HTP · Elite FT (EFT) (discontinued)

HTP EFT-285

The HTP EFT-285 is the 285 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 28,500 to 285,000 BTU/hr input, 262 MBH heating capacity, 203 lb shipping weight and a 10:1 turndown, recorded from the official LP-387 technical table and the LP-657 10:1-generation table.

DiscontinuedCanadian status unknown

Key figures

Max input
285 MBH
Max CSA output
AFUE
Min input
28.5 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

HTP EFT-285 in practice

The EFT-285 is one of the seven Elite FT heating boilers on HTP's retired Elite FT page. The official LP-387 technical specifications table prints 28,500 to 285,000 BTU/hr input, 262 MBH heating capacity, a 203 lb shipping weight, 6.1 gal of boiler water content and a 20" x 32.6" x 20.6" (W x H x D) wall-hung cabinet with 1-1/4" copper SWT supply/return and 1" NPTF gas inlet. For the 285/399 sizes the LP-657 manual for units manufactured on/after 10/30/17 with 10:1 turndown prints the ${BTU(d.min)}-${BTU(d.max)} range used here; LP-387's table prints the earlier 5:1-generation ranges.

The Elite FT is a stainless steel vertical fire-tube, down-fired condensing boiler with a 10:1 turndown, the 926 SIT control (outdoor reset, DHW indirect priority, cascade up to eight boilers, 0-10V BMS input) and Category IV sealed-combustion venting in PVC, CPVC, polypropylene or stainless steel. The retired page prints 'up to a 95.1% AFUE rating with up to a 10 to 1 turndown ratio' and SCAQMD Rule 1146.2 compliance; the 5:1 submittal prints up to 96.3% AFUE for the smaller models. The heat exchanger carries a 12-year limited warranty.

The Elite FT line is retired: HTP's discontinued-products index lists 'Elite FT Heating Boiler' and the EFT documents page remains as archived support. Boilers.ca records it with productStatus 'discontinued' and canadianStatus 'unknown'; no official Canadian sales statement was found. Service an installed unit with a licensed contractor against LP-387 or LP-657.

Best suited to

  • Identifying a retired Elite FT boiler already installed
  • Retrieving the official LP-387/LP-657 documentation for an existing unit
  • Replacement planning with the existing input and capacity known

Applicability and support

Model number
EFT-285
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by HTP. Units are shown with every value; notes flag conflicting sources or missing figures.

HTP EFT-285 specifications
SpecificationValueNote
Input
Input rate, minimum28.5 MBH28,500 BTU/hr per LP-387 (LP-657 Table (models manufactured on/after 10/30/17 with 10:1 turndown) prints 28,500/285,000 BTU/hr; LP-387's table prints 57,000/285,000 for the earlier 5:1-generation units.).
Input rate, maximum285 MBH285,000 BTU/hr per LP-387 (LP-657 Table (models manufactured on/after 10/30/17 with 10:1 turndown) prints 28,500/285,000 BTU/hr; LP-387's table prints 57,000/285,000 for the earlier 5:1-generation units.).
Output
Heating capacity262 MBHAs printed in the LP-387 technical specifications table (367* for the 399 as printed; *N/A Energy Guide).
Efficiency
AFUE (as printed)95.1 %As printed for the model on the retired Elite FT product page and LP-659 submittal (285: AFUE up to 95.1%; 399: thermal efficiency up to 97.1).
Venting and air
Venting3" (150 ft combined)Category IV sealed-combustion direct vent; PVC, CPVC, polypropylene or stainless steel per LP-387. The 5:1 line prints a 200 ft combined limit (150 ft on the 285).
Physical and connections
Shipping weight203 lbAs printed in the LP-387 technical specifications table.
Boiler water content6.1 galAs printed in the LP-387 technical specifications table.
Dimensions (W x H x D)20" x 32.6" x 20.6"As printed in the LP-387 technical specifications table.
Gas inlet connection1" NPTFAs printed in the LP-387 technical specifications table; gas supply pressure NG/LP 3.5"-14" WC.
Water pressure MAWP / relief80 psi / 80 psiAs printed in LP-387 (30 psi for EFT-55 through 199; 80 psi for EFT-285/399).
Heat exchangerStainless steel vertical fire tube (ASME 'H' stamped, National Board listed)LP-392 prints 'All Stainless Steel ASME H Stamped Construction'; LP-391 prints 439 stainless steel for the 5:1 models.
Operating limits and other
CH supply/return connection1-1/4" copper SWTAs printed in the LP-387 technical specifications table; top and bottom supply/return connections (bottom only on EFT-55/80/110).
Turndown10:110:1 per the LP-657 manual and LP-659 submittal for models manufactured on/after 10/30/17.
Control926 SIT control with 2-line/20-character LCD and LED indicatorsOutdoor reset, DHW indirect priority, cascade up to 8 boilers, 0-10V BMS input, last 10 fault codes with date/time per LP-392.
Warranty12-year limited heat-exchanger warrantyLP-392/LP-391 print a 12 year limited warranty; the retired product page prints a twelve year warranty.

Frequently asked questions

What is the input range of the EFT-285?

LP-387 prints 28,500 to 285,000 BTU/hr with 262 MBH heating capacity. For units manufactured on/after 10/30/17 with 10:1 turndown, LP-657 prints the same range used on this record.

What is the EFT-285 turndown?

10:1 per the LP-657 manual and LP-659 submittal for units manufactured on/after 10/30/17.

Is the Elite FT still sold?

No — HTP's discontinued-products index lists the Elite FT Heating Boiler; the pages and manuals remain for support.

Questions about the HTP EFT-285?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.