Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

HTP EFT-285 vs EFT-399

Verdict in brief

The EFT-285 and EFT-399 are the two 10:1-generation Elite FT boilers: the EFT-399 adds 114 MBH of capacity (367 vs 262 MBH), grows to the 25.5 x 36.4 x 23.6 in cabinet at 298 lb, uses a 1-1/2" copper SWT connection and a 4" (200 ft) vent, and prints 97.1 thermal efficiency against the EFT-285's 95.1% AFUE.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EFT-285 and HTP EFT-399
SpecificationHTP EFT-285HTP EFT-399
Input rate, minimum28.5 MBH39.9 MBH
Input rate, maximum285 MBH399 MBH
Heating capacity262 MBH367 MBH
Shipping weight203 lb298 lb
Boiler water content6.1 gal7.9 gal
Dimensions (W x H x D)20" x 32.6" x 20.6"25.5" x 36.4" x 23.6"
CH supply/return connection1-1/4" copper SWT1-1/2" copper SWT
Venting3" (150 ft combined)4" (200 ft combined)
Turndown10:110:1

What actually separates them

LP-657 prints the EFT-285 at 28,500-285,000 BTU/hr and the EFT-399 at 39,900-399,000; heating capacity steps from 262 to 367 MBH and the retired page prints 95.1% AFUE (285) and 97.1 thermal efficiency (399).

The EFT-399 moves to the larger 25.5 x 36.4 x 23.6 in cabinet with 7.9 vs 6.1 gal water content and 298 vs 203 lb shipping weight.

Connections grow from 1-1/4" to 1-1/2" copper SWT (both 1" NPTF gas) and venting from 3" (150 ft) to 4" (200 ft); both are 10:1, 80 PSI MAWP models.

DiscontinuedCanadian status unknown
Input
28.5–285 MBH
Output (max)
AFUE

The HTP EFT-285 is the 285 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 28,500 to 285,000 BTU/hr input, 262 MBH heating capacity, 203 lb shipping weight and a 10:1 turndown, recorded from the official LP-387 technical table and the LP-657 10:1-generation table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
39.9–399 MBH
Output (max)
AFUE

The HTP EFT-399 is the 399 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 39,900 to 399,000 BTU/hr input, 367 MBH heating capacity, 298 lb shipping weight and a 10:1 turndown, recorded from the official LP-387 technical table and the LP-657 10:1-generation table.

Natural gasPropaneHeating-only

Frequently asked questions

What is the EFT-399's input range?

39,900-399,000 BTU/hr in LP-657 (10:1 generation) with 367 MBH heating capacity and 97.1 printed thermal efficiency.

Does the EFT-399 need bigger pipe?

Yes — 1-1/2" copper SWT supply/return and a 4" (200 ft) combined vent against the EFT-285's 1-1/4" and 3" (150 ft).

How much heavier is the EFT-399?

LP-657/LP-387 print 298 lb against 203 lb for the EFT-285, with 7.9 vs 6.1 gal water content.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate