Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

HTP EFTC-140W vs HTP EFTC-199F

Verdict in brief

The HTP EFTC-140W and HTP EFTC-199F are both combination (combi) boilers in the HTP EFT Combi (discontinued) line. The HTP EFTC-140W is rated 28–140 MBH input and 95% AFUE, and the HTP EFTC-199F is rated 19.9–140 MBH input and 95.7% AFUE. Both list the same published input of 140 MBH. HTP EFTC-199F carries the higher published AFUE at 95.7%, against 95%. HTP EFTC-199F lists 150 lb more shipping weight than HTP EFTC-140W (260 lb against 110 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EFTC-140W and HTP EFTC-199F
SpecificationHTP EFTC-140WHTP EFTC-199F
Central-heating input, minimum28 MBH19.9 MBH
Central-heating input, maximum140 MBH140 MBH
AFUE (page table)95 %95.7 %
Turndown5:110:1
DHW input, minimum28 MBH19.9 MBH
DHW input, maximum140 MBH199 MBH
Shipping weight110 lb260 lb
Dimensions (W x H x D)17.25" W x 34" H x 15.5" D15.7" W x 53.7" H x 26.8" D
Venting2" (50 ft) or 3" (100 ft), combined equivalent feet2" (50 ft) or 3" (100 ft), combined equivalent feet
DHW flow rate at 35 °F rise7.1 gpm9.9 gpm
DHW flow rate at 45 °F rise5.5 gpm7.7 gpm
DHW flow rate at 77 °F rise3.2 gpm4.8 gpm
ConnectionsCH supply/return 1" NPT; DHW inlet/outlet 3/4" NPT; gas 1/2" NPT (1/2" x 3/4" bell coupling provided)CH supply/return 1" NPT; DHW inlet/outlet 3/4" NPT; gas 3/4" NPT
Water pressureCH 12-30 psi; DHW maximum 150 psiCH 12-30 psi; DHW maximum 150 psi
ControlNGTX-900C / P-920C_CB-HTPGTX-920C / P-920C_CB-HTP
Heat exchanger and tank316L stainless steel fire tube heat exchanger and stainless steel indirect storage tank316L stainless steel fire tube heat exchanger and stainless steel indirect storage tank
Warranty10-year limited residential / 5-year limited commercial10-year limited, no registration required

What actually separates them

Published ratings: the HTP EFTC-140W is rated 28–140 MBH input and 95% AFUE; the HTP EFTC-199F is rated 19.9–140 MBH input and 95.7% AFUE. Both list the same published input of 140 MBH. HTP EFTC-199F carries the higher published AFUE at 95.7%, against 95%.

HTP EFTC-199F lists 150 lb more shipping weight than HTP EFTC-140W (260 lb against 110 lb). The turndown differs: the HTP EFTC-140W lists 5:1, while the HTP EFTC-199F lists 10:1. The domestic-hot-water input differs: the HTP EFTC-140W lists 28 MBH, while the HTP EFTC-199F lists 19.9 MBH. The domestic-hot-water input differs: the HTP EFTC-140W lists 140 MBH, while the HTP EFTC-199F lists 199 MBH.

Both records print the same input (140 MBH), venting (2" (50 ft) or 3" (100 ft), combined equivalent feet), water pressure (CH 12-30 psi; DHW maximum 150 psi) and heat exchanger and tank (316L stainless steel fire tube heat exchanger and stainless steel indirect storage tank), per the cited sources.

DiscontinuedCanadian status unknown
Input
28–140 MBH
Output (max)
—
AFUE
95 %

The HTP EFTC-140W is the wall-hung 140 MBH class combi of the retired EFT Combi line: 28,000 to 140,000 BTU/hr CH input, 28,000 to 140,000 BTU/hr DHW input and 95% printed AFUE, recorded from the official retired EFT Combi table.

Natural gasPropaneCombi
DiscontinuedCanadian status unknown
Input
19.9–140 MBH
Output (max)
—
AFUE
95.7 %

The HTP EFTC-199F is the floor-standing 199 MBH class combi of the retired EFT Combi line: 19,900 to 140,000 BTU/hr CH input, 19,900 to 199,000 BTU/hr DHW input and 95.7% printed AFUE, recorded from the official retired EFT Combi table.

Natural gasPropaneCombi

Frequently asked questions

Do the two models share the same input?

Yes — both list 140 MBH in the cited documentation.

Which model is more efficient?

The HTP EFTC-199F carries the higher published AFUE at 95.7%, against 95%.

How much heavier is the HTP EFTC-199F?

It ships at 260 lb against 110 lb for the HTP EFTC-140W, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate