HTP EFTU-150WCN vs EFTU-199WCN

Verdict in brief

The EFTU-199WCN is the top Elite Fire Tube Ultra combi: it fires 19,900–199,000 BTU/hr for both CH and DHW and delivers 10.5 GPM at a 35 °F rise against the EFTU-150WCN's 7.9 GPM, with DOE heating capacity up from 138 to 184 MBH. In exchange it must vent in 3" pipe only, deepens to the 18.5 in cabinet and ships at 132 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EFTU-150WCN and HTP EFTU-199WCN
SpecificationHTP EFTU-150WCNHTP EFTU-199WCN
Central-heating input, minimum (natural gas)15 MBH19.9 MBH
Central-heating input, maximum (natural gas)150 MBH199 MBH
DHW input, minimum15 MBH19.9 MBH
DHW input, maximum150 MBH199 MBH
DOE AFUE95 %95 %
Heating capacity (DOE)138 MBH184 MBH
DHW flow rate at 35 °F rise7.9 gpm10.5 gpm
DHW flow rate at 45 °F rise6.1 gpm8.2 gpm
DHW flow rate at 77 °F rise3.6 gpm4.8 gpm
Shipping weight121 lb132 lb
Approximate full boiler weight128.5 lb140.5 lb
VentingExhaust 2" (6–100 ft) or 3" (6–150 ft); intake 2" (0–100 ft) or 3" (0–150 ft)Exhaust and intake 3" only — exhaust 6–150 ft, intake 0–150 ft

What actually separates them

The EFTU-150WCN and EFTU-199WCN share the Elite Fire Tube Ultra combi platform — vertical fire-tube heat exchanger, 10:1 turndown, ECM pump, 95% DOE AFUE — but split on packaging: the 150 stays in the 17 in deep cabinet at 121 lb shipping (128.5 lb full, 2.1 gal water content), while the 199 deepens to 18.5 in, ships at 132 lb (140.5 lb full, 2.8 gal water content) and must be vented in 3" diameter pipe per LP-723.

The hot-water table is the headline: the 199 combi prints 10.5 / 8.2 / 4.8 GPM at 35 / 45 / 77 °F rises against the 150's 7.9 / 6.1 / 3.6 GPM, with DHW input matching the CH range on each model. DOE heating capacity steps from 138 to 184 MBH and the net AHRI rating from 120 to 160 MBH.

Both combis use 1-1/4" male NPT CH supply/return with 3/4" NPT DHW inlet/outlet and gas, a 50 psi heat-exchanger MAWP with 30 psi relief, and the 15-year registered warranty. A project that cannot vent the 199 in 3" pipe must stay at the 150 or smaller.

CurrentCanadian status unknown
Input
15–150 MBH
Output (max)
AFUE
95 %

The HTP EFTU-150WCN is the 150 MBH class wall-hung combi of the Elite Fire Tube Ultra line: 15.0 to 150 MBH input for central heating and the same range for domestic hot water, 95% DOE AFUE, 138 MBH DOE heating capacity and up to 3.6 GPM of DHW at a 77 °F rise.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The HTP EFTU-199WCN is the 199 MBH class wall-hung combi of the Elite Fire Tube Ultra line: 19.9 to 199 MBH input for central heating and the same range for domestic hot water, 95% DOE AFUE, 184 MBH DOE heating capacity and up to 4.8 GPM of DHW at a 77 °F rise.

Natural gasPropaneCombi

Frequently asked questions

Does the EFTU-199WCN need 3" venting?

Yes — LP-723 requires 199/199C models to be vented in 3" diameter pipe (exhaust 6–150 ft, intake 0–150 ft).

How much hot water can the 199 combi deliver?

10.5 GPM at a 35 °F rise, 8.2 GPM at 45 °F and 4.8 GPM at a 77 °F rise per the official table.

Is the 199 combi physically different from the 150 combi?

Yes — the 199 uses the deeper 18.5 in cabinet, ships at 132 lb (against 121 lb) and holds 2.8 gal of water against 2.1 gal.

Not sure which one fits your home?