HTP UFTC-140F vs UFTC-199F

Verdict in brief

The UFTC-199F is the larger UFT Combi floor model: it delivers 9.9 vs 7.1 GPM at a 35 °F rise, fires 19,900-199,000 BTU/hr for DHW, ships at 150 lb against 140 lb and uses a wider 22 x 48 x 18 in cabinet against the 140F's 19 x 45 x 17 in. The 140F prints 96% AFUE against 95% for the 199F.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP UFTC-140F and HTP UFTC-199F
SpecificationHTP UFTC-140FHTP UFTC-199F
Central-heating input, minimum14 MBH19.9 MBH
Central-heating input, maximum140 MBH140 MBH
DHW input, minimum14 MBH19.9 MBH
DHW input, maximum140 MBH199 MBH
AFUE96 %95 %
DHW flow rate at 35 °F rise7.1 gpm9.9 gpm
DHW flow rate at 45 °F rise5.5 gpm7.7 gpm
DHW flow rate at 77 °F rise3.2 gpm4.8 gpm
Weight, floor model140 lb150 lb
Dimensions (W x H x D)19" W x 45" H x 17" D22" W x 48" H x 18" D

What actually separates them

LP-648 Table 8 prints the same input structure as the wall models: 14,000-140,000 BTU/hr CH/DHW on the 140F and 19,900-140,000 CH / 19,900-199,000 DHW on the 199F.

The 199F delivers 9.9/7.7/4.8 GPM at 35/45/77°F rises against 7.1/5.5/3.2, and grows the floor cabinet from 19 x 45 x 17 in to 22 x 48 x 18 in with a 10 lb weight increase.

Both are 10:1-turndown floor combis with 1" NPT CH and 3/4" NPT DHW/gas connections, 2" (50 ft) or 3" (100 ft) venting and a 10-year limited warranty; AFUE prints 96% vs 95%.

DiscontinuedCanadian status unknown
Input
14–140 MBH
Output (max)
AFUE
96 %

The HTP UFTC-140F is the floor-mount 140 MBH class combi of the retired UFT Combi line: 14,000 to 140,000 BTU/hr CH input, 14,000 to 140,000 BTU/hr DHW input and 96% AFUE, recorded from the official LP-648 technical table.

Natural gasPropaneCombi
DiscontinuedCanadian status unknown
Input
19.9–140 MBH
Output (max)
AFUE
95 %

The HTP UFTC-199F is the floor-mount 199 MBH class combi of the retired UFT Combi line: 19,900 to 140,000 BTU/hr CH input, 19,900 to 199,000 BTU/hr DHW input and 95% AFUE, recorded from the official LP-648 technical table.

Natural gasPropaneCombi

Frequently asked questions

What is the difference between the UFTC-140F and UFTC-199F?

DHW input and delivery (14,000-140,000 / 7.1 GPM vs 19,900-199,000 / 9.9 GPM at a 35°F rise), cabinet size and weight, and a 96% vs 95% AFUE print.

Do both floor models vent the same?

Yes — both use 2" (50 ft) or 3" (100 ft) combined venting.

Which floor combi has more hot-water capacity?

The UFTC-199F, at 9.9 GPM at a 35°F rise and 4.8 GPM at 77°F.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.