Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

HTP UFTC-140W vs HTP UFTC-199F

Verdict in brief

The HTP UFTC-140W and HTP UFTC-199F are both combination (combi) boilers in the HTP UFT Combi (discontinued) line. Published ratings: HTP UFTC-140W at 14–140 MBH input and 96% AFUE; HTP UFTC-199F at 19.9–140 MBH input and 95% AFUE. Both list the same published input of 140 MBH. HTP UFTC-140W lists 1 percentage points more AFUE than HTP UFTC-199F (96% against 95%). HTP UFTC-199F lists 40 lb more shipping weight than HTP UFTC-140W (150 lb against 110 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP UFTC-140W and HTP UFTC-199F
SpecificationHTP UFTC-140WHTP UFTC-199F
Central-heating input, minimum14 MBH19.9 MBH
Central-heating input, maximum140 MBH140 MBH
AFUE96 %95 %
Turndown10:110:1
DHW input, minimum14 MBH19.9 MBH
DHW input, maximum140 MBH199 MBH
Water capacity1 gal storage tank + 4 gal heat exchanger (5 gal total)1.5 gal storage tank + 3.5 gal heat exchanger (5 gal total)
Weight, wall model110 lb150 lb
Dimensions (W x H x D)17.5" W x 34" H x 15.4" D22" W x 48" H x 18" D
Venting2" (50 ft) or 3" (100 ft), combined equivalent feet2" (50 ft) or 3" (100 ft), combined equivalent feet
DHW flow rate at 35 °F rise7.1 gpm9.9 gpm
DHW flow rate at 45 °F rise5.5 gpm7.7 gpm
DHW flow rate at 77 °F rise3.2 gpm4.8 gpm
ConnectionsCH supply/return 1" NPT; DHW inlet/outlet 3/4" NPT; gas 3/4" NPTCH supply/return 1" NPT; DHW inlet/outlet 3/4" NPT; gas 3/4" NPT
Water pressureCH minimum 12 / maximum 30 psi; DHW maximum 150 psiCH minimum 12 / maximum 30 psi; DHW maximum 150 psi
ControlNGTX-900C / P-920C_CB-HTPNGTX-900C / P-920C_CB-HTP
Heat exchanger and tank316L stainless steel, ASME 'H' stamped, with internal 316L stainless steel indirect storage tank316L stainless steel, ASME 'H' stamped, with internal 316L stainless steel indirect storage tank
Warranty10-year limited warranty10-year limited warranty

What actually separates them

Published ratings: the HTP UFTC-140W is rated 14–140 MBH input and 96% AFUE; the HTP UFTC-199F is rated 19.9–140 MBH input and 95% AFUE. Both list the same published input of 140 MBH. HTP UFTC-140W lists 1 percentage points more AFUE than HTP UFTC-199F (96% against 95%).

HTP UFTC-199F lists 40 lb more shipping weight than HTP UFTC-140W (150 lb against 110 lb). The domestic-hot-water input differs: the HTP UFTC-140W lists 14 MBH, while the HTP UFTC-199F lists 19.9 MBH. The domestic-hot-water input differs: the HTP UFTC-140W lists 140 MBH, while the HTP UFTC-199F lists 199 MBH. The boiler water content differs: the HTP UFTC-140W lists 1 gal storage tank + 4 gal heat exchanger (5 gal total), while the HTP UFTC-199F lists 1.5 gal storage tank + 3.5 gal heat exchanger (5 gal total).

Both records print the same input (140 MBH), turndown (10:1), venting (2" (50 ft) or 3" (100 ft), combined equivalent feet) and connections (CH supply/return 1" NPT; DHW inlet/outlet 3/4" NPT; gas 3/4" NPT), per the cited sources.

DiscontinuedCanadian status unknown
Input
14–140 MBH
Output (max)
AFUE
96 %

The HTP UFTC-140W is the wall-mount 140 MBH class combi of the retired UFT Combi line: 14,000 to 140,000 BTU/hr CH input, 14,000 to 140,000 BTU/hr DHW input and 96% AFUE, recorded from the official LP-648 technical table.

Natural gasPropaneCombi
DiscontinuedCanadian status unknown
Input
19.9–140 MBH
Output (max)
AFUE
95 %

The HTP UFTC-199F is the floor-mount 199 MBH class combi of the retired UFT Combi line: 19,900 to 140,000 BTU/hr CH input, 19,900 to 199,000 BTU/hr DHW input and 95% AFUE, recorded from the official LP-648 technical table.

Natural gasPropaneCombi

Frequently asked questions

Do the two models share the same input?

Yes — both list 140 MBH in the cited documentation.

Which model is more efficient?

The HTP UFTC-140W carries the higher published AFUE at 96%, against 95%.

How much heavier is the HTP UFTC-199F?

It ships at 150 lb against 110 lb for the HTP UFTC-140W, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate