Skip to content
Boilers.caby ROMA Heating & Cooling

HTP · UFT Combi (discontinued)

HTP UFTC-140W

The HTP UFTC-140W is the wall-mount 140 MBH class combi of the retired UFT Combi line: 14,000 to 140,000 BTU/hr CH input, 14,000 to 140,000 BTU/hr DHW input and 96% AFUE, recorded from the official LP-648 technical table.

DiscontinuedCanadian status unknown

Key figures

Max input
140 MBH
Max CSA output
AFUE
96 %
Min input
14 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

HTP UFTC-140W in practice

The UFTC-140W is one of the four UFT Combi configurations (UFTC-140/199 in wall "W" or floor "F" mount) documented on HTP's retired UFT Combination documents page. LP-648 Table 8 prints 14,000-140,000 BTU/hr central-heating input, 14,000-140,000 BTU/hr DHW input, 96% AFUE, 110 lb wall-model weight, a 17.5" W x 34" H x 15.4" D cabinet, DHW flows of 7.1 / 5.5 / 3.2 GPM at 35 / 45 / 77°F rise and 1 gal storage tank + 4 gal heat exchanger (5 gal total).

The UFT Combi uses an ASME 'H' stamped 316L stainless steel fire-tube heat exchanger with an internal 316L stainless steel indirect storage tank, a 10:1 modulating burner, a built-in low water cut-off, an installed internal pump and the NGTX-900C / P-920C_CB-HTP control. It vents as a Category IV sealed-combustion appliance in 2" (50 ft) or 3" (100 ft) pipe, connects CH at 1" NPT, DHW at 3/4" NPT and gas at 3/4" NPT, and carries a 10-year limited warranty. The LP-646 submittal prints up to 96% AFUE.

The UFT Combi is retired: the official documents page states verbatim 'This products has been discontinued, please see the below documentation for support.' and the discontinued index lists 'UFT Combi Boiler - Wall & Floor'. Boilers.ca records it with productStatus 'discontinued' and canadianStatus 'unknown'; no official Canadian sales statement was found. Service an installed unit with a licensed contractor against LP-648.

Best suited to

  • Identifying a retired UFT Combi already installed
  • Retrieving the official LP-648/LP-646/mktlit-115 documentation
  • Replacement planning for a wall or floor combi with a known DHW draw

Applicability and support

Model number
UFTC-140W
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by HTP. Units are shown with every value; notes flag conflicting sources or missing figures.

HTP UFTC-140W specifications
SpecificationValueNote
Input
Central-heating input, minimum14 MBH14,000 BTU/hr as printed in LP-648 Table 8 and the mktlit-115 brochure.
Central-heating input, maximum140 MBH140,000 BTU/hr as shipped; LP-648's footnote states 199 models can be increased up to 199,000 BTU/hr with a larger external pump in the primary loop.
Efficiency
AFUE96 %LP-648 Table 8 prints 96%; the mktlit-115 brochure prints 96.
Domestic hot water
DHW input, minimum14 MBH14,000 BTU/hr as printed in LP-648 Table 8 and the brochure.
DHW input, maximum140 MBH140,000 BTU/hr as printed in LP-648 Table 8 and the brochure.
DHW flow rate at 35 °F rise7.1 gpmAs printed in LP-648 Table 8.
DHW flow rate at 45 °F rise5.5 gpmAs printed in LP-648 Table 8.
DHW flow rate at 77 °F rise3.2 gpmAs printed in LP-648 Table 8.
Venting and air
Venting2" (50 ft) or 3" (100 ft), combined equivalent feetCategory IV sealed-combustion direct vent / power vent; CPVC, PVC, PP per the mktlit-115 brochure.
Physical and connections
Weight, wall model110 lbAs printed in LP-648 Table 8 (wall-mount and floor-model weight rows).
Dimensions (W x H x D)17.5" W x 34" H x 15.4" DAs printed in LP-648 Table 8.
Water pressureCH minimum 12 / maximum 30 psi; DHW maximum 150 psiAs printed in LP-648 Table 8.
Water capacity1 gal storage tank + 4 gal heat exchanger (5 gal total)As printed in LP-648 Table 8 (internal storage tank + heat exchanger).
Heat exchanger and tank316L stainless steel, ASME 'H' stamped, with internal 316L stainless steel indirect storage tankPer the LP-646 submittal.
Operating limits and other
ConnectionsCH supply/return 1" NPT; DHW inlet/outlet 3/4" NPT; gas 3/4" NPTAs printed in LP-648 Table 8 and the brochure connection diagram.
ControlNGTX-900C / P-920C_CB-HTPAs printed in LP-648 Table 8.
Turndown10:1LP-646 submittal: 'Modulating burner with a turn down of up to 10 to 1'; LP-648 also describes the 199's factory 140,000 max input configuration.
Warranty10-year limited warrantyLP-646 submittal prints a 10 Year Limited Warranty.

Frequently asked questions

Is the UFTC-140W a combi?

Yes — the UFT Combi combines central heating and domestic hot water; LP-648 Table 8 prints CH input 14,000-140,000 and DHW input 14,000-140,000 BTU/hr.

Is the UFT Combi discontinued?

Yes — the official documents page states 'This products has been discontinued, please see the below documentation for support.' and the discontinued index lists the UFT Combi Boiler (Wall & Floor).

What is the maximum DHW input of the UFTC-140W?

140,000 BTU/hr as printed in LP-648 Table 8.

Questions about the HTP UFTC-140W?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate