IBC DC 15-95 vs DC 15-96

Verdict in brief

The DC 15-95 and DC 15-96 are the closest pair in the DC line: nearly identical input and output, but IBC rates the 15-96 at 96% AFUE against the 15-95's 95%, and the 15-96 weighs 105 lb versus 97 lb with a larger 0.5 USG vessel.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC DC 15-95 and IBC DC 15-96
SpecificationIBC DC 15-95IBC DC 15-96
Input, minimum15 MBH15 MBH
Input, maximum95 MBH96 MBH
CSA output, minimum14.4 MBH14.5 MBH
CSA output, maximum85.5 MBH85.9 MBH
Efficiency (AFUE)95 %96 %
DHW input15 – 95 MBH15 – 96 MBH
Max. DHW flow rate3 USgpm3 USgpm
Power use at full fire (internal pump)128 W128 W
Weight (empty)97 lb105 lb
Pressure vessel water content0.37 USG / 1.4 L0.5 USG / 1.9 L
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

The two models share the DC combi platform, coil ratings, gas pressure, altitude approval and venting limits. Their published ratings differ only slightly: 15–95 MBH input / 14.4–85.5 MBH output on the 15-95 versus 15–96 MBH input / 14.5–85.9 MBH output on the 15-96, with 4.4–27.8 kW against 4.4–28.1 kW.

The meaningful difference is efficiency: IBC rates the 15-96 at 96% AFUE, the highest in the DC line, while the 15-95 is rated 95%. Both allow a 3.0 USgpm maximum DHW flow and share the 0.5 USgpm activation threshold.

Physically the 15-96 is heavier at 105 lb (48 kg) versus 97 lb (44 kg) and holds 0.5 USG (1.9 L) versus 0.37 USG (1.4 L). Both are covered by DC I&O manual 120-183-A-R11, and both are discontinued.

IBC Technologies

IBC DC 15-95

DiscontinuedHistorically in Canada
Input
15–95 MBH
Output (max)
85.5 MBH
AFUE
95 %

The IBC DC 15-95 is a discontinued DC combi rated 15–95 MBH input and 14.4–85.5 MBH output at 95% AFUE, with a 3.0 USgpm maximum DHW flow and 120 ft of 3" venting per side.

Natural gasPropaneCombi

IBC Technologies

IBC DC 15-96

DiscontinuedHistorically in Canada
Input
15–96 MBH
Output (max)
85.9 MBH
AFUE
96 %

The IBC DC 15-96 is the highest-efficiency model in the discontinued DC combi line: 96% AFUE, 15–96 MBH input, 14.5–85.9 MBH output, a 3.0 USgpm maximum DHW flow and 0.5 USG of vessel water.

Natural gasPropaneCombi

Frequently asked questions

Why is the DC 15-96 more efficient than the DC 15-95?

IBC's DC specification table rates the 15-96 at 96% AFUE and the 15-95 at 95%; the two are otherwise near-identical on the published rows.

Which DC 15-series model holds more water?

The DC 15-96, at 0.5 USG (1.9 L), against 0.37 USG (1.4 L) on the 15-95.

Are both covered by the same manual?

Yes. Both are listed in DC I&O manual 120-183-A-R11 (April 2020).

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate