IBC DC 15-95

The IBC DC 15-95 is a discontinued DC combi rated 15–95 MBH input and 14.4–85.5 MBH output at 95% AFUE, with a 3.0 USgpm maximum DHW flow and 120 ft of 3" venting per side.

DiscontinuedHistorically in Canada

Key figures

Max input
95 MBH
Max CSA output
85.5 MBH
AFUE
95 %
Min input
15 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

IBC DC 15-95 in practice

The DC 15-95 sat just above the smallest DC combi, covering 15–95 MBH CSA input (4.4–27.8 kW) for 14.4–85.5 MBH output (4.2–25.0 kW) at 95% AFUE. Like the rest of the line it was a wall-hung combination boiler with a 43.5 psig space-heating coil and a 150 psig domestic-hot-water coil, shipped with a 30 psig relief valve.

Its DHW side allows a maximum flow of 3.0 USgpm, with activation at 0.5 USgpm and DHW temperatures of 104–149°F. The unit weighs 97 lb (44 kg), holds 0.37 USG (1.4 L) and draws 128 W at full fire with the internal pump; maximum boiler flow is 10 USgpm and the minimum is 2 USgpm.

The 15-95 is one of the models covered by DC I&O manual 120-183-A-R11 (April 2020). Venting is 120 equivalent feet in 3" or 35 feet in 2" per side, and the DC Series is discontinued, with documentation retained on IBC's Technical Information Portal.

Best suited to

  • Owners documenting an existing DC 15-95 against IBC's published spec table
  • Small to mid-size homes where the 85.5 MBH output matches the heat loss
  • Contractors comparing the 15-95 with the nearly identical 15-96

Applicability and support

Model number
DC 15-95
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.

IBC DC 15-95 specifications
SpecificationValueNote
Input
Input, minimum15 MBH4.4 kW
Input, maximum95 MBH27.8 kW
Output
CSA output, minimum14.4 MBH4.2 kW
CSA output, maximum85.5 MBH25.0 kW
Efficiency
Efficiency (AFUE)95 %Per the DC specification table.
Domestic hot water
DHW input15 – 95 MBH4.4 – 27.8 kW
Max. DHW flow rate3 USgpm
Flow to activate DHW0.5 USgpm
Domestic hot waterIntegrated DHW coil in a combination boiler
Venting and air
Max. equivalent vent length, 3"120 ftEach side.
Max. equivalent vent length, 2"35 ftEach side.
Physical and connections
Weight (empty)97 lb44 kg
Pressure vessel water content0.37 USG / 1.4 L
Electrical
Power use at full fire (internal pump)128 W120 V / 60 Hz.
Operating limits and other
Maximum boiler flow rate10 USgpm
Minimum boiler flow rate2 USgpm
FuelNatural gas or propaneThe DC/HC specification table notes conversion kits must be ordered separately.
Gas supply pressure5 – 14 in. w.c.
Ambient temperature32 – 122 °F0 – 50°C.
Space-heating water temperature50 – 194 °F10 – 90°C.
Domestic hot water temperature104 – 149 °F40 – 65°C.
Max. operating pressure, space-heating coil43.5 psigDHW coil rated 150 psig; the unit ships with a 30 psig pressure relief valve.
Altitude rating12,000 ft

Frequently asked questions

What is the difference between the DC 15-95 and DC 15-96?

The ratings are nearly identical, but IBC lists 95% AFUE for the 15-95 and 96% for the 15-96, with slightly different input and output kW figures; the 15-96 also weighs 105 lb against the 15-95's 97 lb.

Is the DC 15-95 still sold?

No. The DC Series is discontinued and documented on IBC's Technical Information Portal.

Which manual covers the DC 15-95?

I&O manual 120-183-A-R11 (April 2020) lists the DC 15-95 among the models it covers.

Questions about the IBC DC 15-95?