Comparison

IBC DC 15-96 vs DC 29-106

Verdict in brief

The DC 29-106 adds about 10 MBH of input and 8.4 MBH of output over the DC 15-96 but drops from 96% to 94% AFUE, raises the minimum fire from 15 to 28.5 MBH, and moves to a 3 USgpm minimum boiler flow. The 15-96 is the more efficient of the two.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC DC 15-96 and IBC DC 29-106
SpecificationIBC DC 15-96IBC DC 29-106
Input, minimum15 MBH28.5 MBH
Input, maximum96 MBH106 MBH
CSA output, minimum14.5 MBH26.3 MBH
CSA output, maximum85.9 MBH94.3 MBH
Efficiency (AFUE)96 %94 %
DHW input15 – 96 MBH28.5 – 106 MBH
Max. DHW flow rate3 USgpm3.3 USgpm
Power use at full fire (internal pump)128 W128 W
Weight (empty)105 lb85 lb
Pressure vessel water content0.5 USG / 1.9 L0.37 USG / 1.4 L
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

The 29-106 covers 28.5–106 MBH input and 26.3–94.3 MBH output, while the 15-96 covers 15–96 MBH input and 14.5–85.9 MBH output. The extra headroom is modest, but the 29-106's minimum fire is nearly double the 15-96's, which matters in a low-load home where the boiler spends most of its time at part load.

Efficiency moves the other way: IBC rates the 15-96 at 96% AFUE and the 29-106 at 94%. DHW flow rises slightly to 3.3 USgpm on the 29-106 from 3.0 USgpm, both with 0.5 USgpm activation, and the 29-106's minimum boiler flow steps up to 3 USgpm from 2.

The 29-106 is lighter at 85 lb (39 kg) against the 15-96's 105 lb (48 kg), and its output-kW row carries the DC-page discrepancy: the DC table prints 8.9–32.3 kW while the HC table prints 7.7–27.6 kW for the same range. Manuals differ too: 120-183-A-R9 for the 29-106, 120-183-A-R11 for the 15-96.

IBC Technologies

IBC DC 15-96

DiscontinuedHistorically in Canada
Input
15–96 MBH
Output (max)
85.9 MBH
AFUE
96 %

The IBC DC 15-96 is the highest-efficiency model in the discontinued DC combi line: 96% AFUE, 15–96 MBH input, 14.5–85.9 MBH output, a 3.0 USgpm maximum DHW flow and 0.5 USG of vessel water.

Natural gasPropaneCombi

IBC Technologies

IBC DC 29-106

DiscontinuedHistorically in Canada
Input
28.5–106 MBH
Output (max)
94.3 MBH
AFUE
94 %

The IBC DC 29-106 is a discontinued DC combi rated 28.5–106 MBH input and 26.3–94.3 MBH output at 94% AFUE. Its DC spec-table output-kW cell is printed 8.9–32.3, a figure the HC table prints as 7.7–27.6 for the same range.

Natural gasPropaneCombi

Frequently asked questions

Which of these DC models is more efficient?

The DC 15-96, at 96% AFUE; the DC 29-106 is rated 94%.

How much more output does the DC 29-106 have?

About 8.4 MBH at the top end: 94.3 MBH versus 85.9 MBH CSA output.

Which manual covers the DC 29-106?

DC I&O manual 120-183-A-R9; the 15-96 is covered by 120-183-A-R11.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate