IBC DC 29-106

The IBC DC 29-106 is a discontinued DC combi rated 28.5–106 MBH input and 26.3–94.3 MBH output at 94% AFUE. Its DC spec-table output-kW cell is printed 8.9–32.3, a figure the HC table prints as 7.7–27.6 for the same range.

DiscontinuedHistorically in Canada

Key figures

Max input
106 MBH
Max CSA output
94.3 MBH
AFUE
94 %
Min input
28.5 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

IBC DC 29-106 in practice

The DC 29-106 covers 28.5–106 MBH CSA input (8.4–31.0 kW) for 26.3–94.3 MBH output at 94% AFUE. It was a wall-hung combi with a 43.5 psig space-heating coil and a 150 psig DHW coil, and its maximum DHW flow of 3.3 USgpm sits between the 15-96's 3.0 and the larger models' 4.0 USgpm.

One data point needs care: IBC's DC specification table prints the 29-106 output as 8.9–32.3 kW, the same figure shown in the DC 33-124 column, while the HC specification table prints 7.7–27.6 kW for the same 29-106 output range. Boilers.ca records the DC page as printed and notes the cross-table difference rather than choosing a figure.

The 29-106 weighs 85 lb (39 kg), holds 0.37 USG (1.4 L), draws 128 W at full fire with the internal pump and runs 10 USgpm maximum / 3 USgpm minimum boiler flow. It is covered by DC I&O manual 120-183-A-R9 and vents 120 equivalent feet in 3" or 35 feet in 2" per side.

Best suited to

  • Owners identifying a DC 29-106 and its printed ratings
  • Homes where roughly 94 MBH output matches the original combi sizing
  • Technicians cross-checking the DC and HC specification tables

Applicability and support

Model number
DC 29-106
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.

IBC DC 29-106 specifications
SpecificationValueNote
Input
Input, minimum28.5 MBH8.4 kW
Input, maximum106 MBH31.0 kW
Output
CSA output, minimum26.3 MBH8.9 kW
CSA output, maximum94.3 MBH8.9 – 32.3 kW as printed on the DC specification table (the same figure appears in the DC 33-124 column); the HC table prints 7.7–27.6 kW for this output range.
Efficiency
Efficiency (AFUE)94 %Per the DC specification table.
Domestic hot water
DHW input28.5 – 106 MBH8.4 – 31.0 kW
Max. DHW flow rate3.3 USgpm
Flow to activate DHW0.5 USgpm
Domestic hot waterIntegrated DHW coil in a combination boiler
Venting and air
Max. equivalent vent length, 3"120 ftEach side.
Max. equivalent vent length, 2"35 ftEach side.
Physical and connections
Weight (empty)85 lb39 kg
Pressure vessel water content0.37 USG / 1.4 L
Electrical
Power use at full fire (internal pump)128 W120 V / 60 Hz.
Operating limits and other
Maximum boiler flow rate10 USgpm
Minimum boiler flow rate3 USgpm
FuelNatural gas or propaneThe DC/HC specification table notes conversion kits must be ordered separately.
Gas supply pressure5 – 14 in. w.c.
Ambient temperature32 – 122 °F0 – 50°C.
Space-heating water temperature50 – 194 °F10 – 90°C.
Domestic hot water temperature104 – 149 °F40 – 65°C.
Max. operating pressure, space-heating coil43.5 psigDHW coil rated 150 psig; the unit ships with a 30 psig pressure relief valve.
Altitude rating12,000 ft

Frequently asked questions

Why does the DC 29-106 output show two different kW figures?

IBC's DC specification table prints 8.9–32.3 kW (the same as its DC 33-124 column), while the HC table prints 7.7–27.6 kW for the same output range. Boilers.ca notes both and does not substitute one for the other.

Which manual covers the DC 29-106?

I&O manual 120-183-A-R9 lists the DC 29-106 among the models it covers.

What is the DC 29-106's DHW flow?

A maximum of 3.3 USgpm, with activation at 0.5 USgpm, per the DC specification table.

Questions about the IBC DC 29-106?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate