IBC DC 29-106 vs DC 33-124

Verdict in brief

The DC 33-124 lifts the DC line to 124 MBH input and 110.3 MBH output while staying at 94% AFUE like the 29-106. It allows a 4.0 USgpm maximum DHW flow against 3.3, holds more water (0.5 vs 0.37 USG), and both models weigh 85 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC DC 29-106 and IBC DC 33-124
SpecificationIBC DC 29-106IBC DC 33-124
Input, minimum28.5 MBH33 MBH
Input, maximum106 MBH124 MBH
CSA output, minimum26.3 MBH30.4 MBH
CSA output, maximum94.3 MBH110.3 MBH
Efficiency (AFUE)94 %94 %
DHW input28.5 – 106 MBH33 – 124 MBH
Max. DHW flow rate3.3 USgpm4 USgpm
Power use at full fire (internal pump)128 W130 W
Weight (empty)85 lb85 lb
Pressure vessel water content0.37 USG / 1.4 L0.5 USG / 1.9 L
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

The 33-124 covers 33–124 MBH input and 30.4–110.3 MBH output, against the 29-106's 28.5–106 MBH input and 26.3–94.3 MBH output. Both are rated 94% AFUE, so the step up buys capacity rather than efficiency.

The DHW side improves more noticeably: maximum flow rises from 3.3 to 4.0 USgpm, while activation stays at 0.5 USgpm and DHW temperatures remain 104–149°F. The 33-124 also carries the larger 0.5 USG (1.9 L) vessel and an 11 USgpm maximum boiler flow against the 29-106's 10 USgpm.

Both models weigh 85 lb (39 kg), and both carry the DC table's 8.9–32.3 kW output-kW figure — on the 29-106 it duplicates the 33-124 column and conflicts with the HC table's 7.7–27.6 kW. The 29-106 is covered by manual 120-183-A-R9; the 33-124 is not named in either captured DC I&O manual.

IBC Technologies

IBC DC 29-106

DiscontinuedHistorically in Canada
Input
28.5–106 MBH
Output (max)
94.3 MBH
AFUE
94 %

The IBC DC 29-106 is a discontinued DC combi rated 28.5–106 MBH input and 26.3–94.3 MBH output at 94% AFUE. Its DC spec-table output-kW cell is printed 8.9–32.3, a figure the HC table prints as 7.7–27.6 for the same range.

Natural gasPropaneCombi

IBC Technologies

IBC DC 33-124

DiscontinuedHistorically in Canada
Input
33–124 MBH
Output (max)
110.3 MBH
AFUE
94 %

The IBC DC 33-124 is a discontinued DC combi rated 33–124 MBH input and 30.4–110.3 MBH output at 94% AFUE, with a 4.0 USgpm maximum DHW flow and 0.5 USG of vessel water.

Natural gasPropaneCombi

Frequently asked questions

Do the DC 29-106 and DC 33-124 have the same efficiency?

Yes. Both are rated 94% AFUE in IBC's DC specification table.

Why does the DC 29-106 output kW match the 33-124?

The DC table prints 8.9–32.3 kW for both; the HC table prints 7.7–27.6 kW for the 29-106 range, so Boilers.ca flags the DC page as printed rather than treating the duplicate as correct.

Which manual covers the DC 33-124?

Neither captured DC I&O manual names the 33-124; Boilers.ca cites the specification table and the shared DC/HC controller and user documents.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate