IBC DC 33-124 vs DC 20-125

Verdict in brief

The DC 33-124 and DC 20-125 land within half a MBH of each other at the top end (110.3 vs 110.8 MBH output), but the 20-125 fires down to 20 MBH instead of 33, is rated 95% AFUE instead of 94%, and weighs 105 lb against 85 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC DC 33-124 and IBC DC 20-125
SpecificationIBC DC 33-124IBC DC 20-125
Input, minimum33 MBH20 MBH
Input, maximum124 MBH125 MBH
CSA output, minimum30.4 MBH18.6 MBH
CSA output, maximum110.3 MBH110.8 MBH
Efficiency (AFUE)94 %95 %
DHW input33 – 124 MBH20 – 125 MBH
Max. DHW flow rate4 USgpm4 USgpm
Power use at full fire (internal pump)130 W130 W
Weight (empty)85 lb105 lb
Pressure vessel water content0.5 USG / 1.9 L0.5 USG / 1.9 L
Max. operating pressure, space-heating coil43.5 psig43.5 psig
Max. equivalent vent length, 3"120 ft120 ft
Max. equivalent vent length, 2"35 ft35 ft

What actually separates them

The 20-125 covers 20–125 MBH input and 18.6–110.8 MBH output; the 33-124 covers 33–124 MBH input and 30.4–110.3 MBH output. Despite the different number sequences, the maximum outputs are almost the same — the choice between them is really about the bottom of the range.

At 20 MBH the 20-125 can modulate lower than the 33-124's 33 MBH, and IBC rates it one point higher at 95% AFUE against 94%. DHW behaviour matches at 4.0 USgpm maximum flow and 0.5 USgpm activation, as do the 0.5 USG vessel, 11 USgpm maximum flow and 3 USgpm minimum.

The 20-125 is heavier at 105 lb (48 kg) versus 85 lb (39 kg). It appears in both DC I&O manuals (120-183-A-R11 and 120-183-A-R9), while the 33-124 is not named in either captured manual. Both remain at 120 ft of 3" / 35 ft of 2" venting per side.

IBC Technologies

IBC DC 33-124

DiscontinuedHistorically in Canada
Input
33–124 MBH
Output (max)
110.3 MBH
AFUE
94 %

The IBC DC 33-124 is a discontinued DC combi rated 33–124 MBH input and 30.4–110.3 MBH output at 94% AFUE, with a 4.0 USgpm maximum DHW flow and 0.5 USG of vessel water.

Natural gasPropaneCombi

IBC Technologies

IBC DC 20-125

DiscontinuedHistorically in Canada
Input
20–125 MBH
Output (max)
110.8 MBH
AFUE
95 %

The IBC DC 20-125 is a discontinued DC combi rated 20–125 MBH input and 18.6–110.8 MBH output at 95% AFUE, with a 4.0 USgpm maximum DHW flow, 105 lb weight and 120 ft of 3" venting per side.

Natural gasPropaneCombi

Frequently asked questions

Which has more output, the DC 33-124 or the DC 20-125?

Effectively the same: 110.3 MBH on the 33-124 and 110.8 MBH on the 20-125.

Which one modulates lower?

The DC 20-125, whose minimum input is 20 MBH against the 33-124's 33 MBH.

Why does the DC 20-125 weigh more?

IBC lists 105 lb (48 kg) for the 20-125 and 85 lb (39 kg) for the 33-124; the two use different assemblies per the specification table.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate