IBC Technologies · DC Series (discontinued)

IBC DC 20-125

The IBC DC 20-125 is a discontinued DC combi rated 20–125 MBH input and 18.6–110.8 MBH output at 95% AFUE, with a 4.0 USgpm maximum DHW flow, 105 lb weight and 120 ft of 3" venting per side.

DiscontinuedHistorically in Canada

Key figures

Max input
125 MBH
Max CSA output
110.8 MBH
AFUE
95 %
Min input
20 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

IBC DC 20-125 in practice

The DC 20-125 covers 20–125 MBH CSA input (5.6–36.6 kW) for 18.6–110.8 MBH output (5.4–32.5 kW) at 95% AFUE. Its low minimum input of 20 MBH made it the second-smallest low-fire point in the DC line, while its 110.8 MBH output lands within a fraction of the larger DC 33-124's 110.3 MBH.

It is a wall-hung combi with the standard DC coil ratings (43.5 psig space heating, 150 psig DHW) and a 4.0 USgpm maximum DHW flow, activating at 0.5 USgpm. The unit weighs 105 lb (48 kg), holds 0.5 USG (1.9 L) and draws 130 W at full fire with the internal pump; maximum boiler flow is 11 USgpm and the minimum is 3 USgpm.

The 20-125 appears in both DC I&O coverage lists (120-183-A-R11 and 120-183-A-R9). It vents 120 equivalent feet in 3" or 35 feet in 2" per side, and the DC Series is discontinued but still documented on IBC's Technical Information Portal.

Best suited to

  • Owners documenting an existing DC 20-125 installation
  • Homes wanting a low 20 MBH minimum fire with up to 110.8 MBH output
  • Technicians comparing the 20-125 with the DC 33-124 and 33-160

Applicability and support

Model number
DC 20-125
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.

IBC DC 20-125 specifications
SpecificationValueNote
Input
Input, minimum20 MBH5.6 kW
Input, maximum125 MBH36.6 kW
Output
CSA output, minimum18.6 MBH5.4 kW
CSA output, maximum110.8 MBH32.5 kW
Efficiency
Efficiency (AFUE)95 %Per the DC specification table.
Domestic hot water
DHW input20 – 125 MBH5.6 – 36.6 kW
Max. DHW flow rate4 USgpm
Flow to activate DHW0.5 USgpm
Domestic hot waterIntegrated DHW coil in a combination boiler
Venting and air
Max. equivalent vent length, 3"120 ftEach side.
Max. equivalent vent length, 2"35 ftEach side.
Physical and connections
Weight (empty)105 lb48 kg
Pressure vessel water content0.5 USG / 1.9 L
Electrical
Power use at full fire (internal pump)130 W120 V / 60 Hz.
Operating limits and other
Maximum boiler flow rate11 USgpm
Minimum boiler flow rate3 USgpm
FuelNatural gas or propaneThe DC/HC specification table notes conversion kits must be ordered separately.
Gas supply pressure5 – 14 in. w.c.
Ambient temperature32 – 122 °F0 – 50°C.
Space-heating water temperature50 – 194 °F10 – 90°C.
Domestic hot water temperature104 – 149 °F40 – 65°C.
Max. operating pressure, space-heating coil43.5 psigDHW coil rated 150 psig; the unit ships with a 30 psig pressure relief valve.
Altitude rating12,000 ft

Frequently asked questions

Why does the DC 20-125 weigh more than the 33-124?

IBC lists 105 lb (48 kg) for the 20-125 and 85 lb (39 kg) for the 33-124, even though their output ratings are close; the two models use different assemblies per the specification table.

Which manual covers the DC 20-125?

Both DC I&O manuals captured for this record cover it: 120-183-A-R11 and 120-183-A-R9.

What is the DC 20-125's minimum input?

20 MBH (5.6 kW) per the DC specification table.

Questions about the IBC DC 20-125?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate