Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

IBC VX 110 vs Viessmann Vitodens 200-W B2HE-120

Verdict in brief

The IBC VX 110 and Viessmann Vitodens 200-W B2HE-120 are 95% AFUE heating-only wall-hung boilers in the 110-120 MBH class with very different modulation depths: IBC fires 16.9 to 110 MBH at up to 6.5:1 turndown, while Viessmann fires 8.5 to 120 MBH at up to 14:1. The B2HE's 8.5 MBH minimum fire tracks small loads well; the VX's 67 lb weight suits tight retrofit walls; a heat-loss calculation picks the size.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of IBC VX 110 and Viessmann Vitodens 200-W B2HE-120
SpecificationIBC VX 110Viessmann Vitodens 200-W B2HE-120
Input, minimum16.9 MBH8.5 MBH
Input, maximum110 MBH120 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 6.5:1up to 14:1
Weight (empty)67 lb108 lb
FuelNatural gas or propaneNatural gas or liquid propane
Domestic hot waterNot a combi; IBC documents direct connection of an indirect tankNot a combi; pair with an indirect tank

What actually separates them

Both are heating-only condensing boilers rated 95% AFUE on natural gas or propane, in the same general 110-120 MBH class, but the published modulation story is very different. IBC lists the VX 110 at 16.9 to 110 MBH (5 to 32.2 kW) with up to 6.5:1 turndown, while Viessmann Canada lists the B2HE-120 at 8.5 to 120 MBH (2.5 to 35.2 kW) and claims up to 14:1 turndown on natural gas at high fire.

The real-world gap is the minimum fire: 8.5 MBH on the B2HE-120 versus 16.9 MBH on the VX 110. In a well-insulated home with modest mild-weather loads, the Viessmann platform can run far lower before reaching its low-fire limit, which is where a condensing boiler earns its efficiency; the VX needs more load to stay in continuous modulation.

The IBC VX 110 answers with installability: it weighs 67 lb (30.4 kg) against the B2HE-120's 108 lb (49 kg), and IBC allows 240 equivalent feet of 3" or 100 feet of 2" venting per side, while the B2HE page quotes about 198 ft for its venting. Both need an indirect tank for domestic hot water, and both should be matched to a heat-loss calculation rather than home size.

IBC Technologies

IBC VX 110

CurrentSold in Canada
Input
16.9–110 MBH
Output (max)
101.5 MBH
AFUE
95 %

The IBC VX 110 is the smallest VX Series boiler: 16.9 to 110 MBH input, 95% AFUE, wall-hung on the V-10 controller, with 2" venting allowed to 100 feet and 3" to 240 feet per side.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
8.5–120 MBH
Output (max)
—
AFUE
95 %

The Vitodens 200-W B2HE-120 is the mid-range model of Viessmann Canada's flagship B2HE series: 8.5 to 120 MBH input at 95% AFUE in the 108 lb cabinet, covering many detached Lower Mainland homes.

Natural gasPropaneHeating-only

Frequently asked questions

Which boiler modulates lower?

The Viessmann B2HE-120 publishes an 8.5 MBH minimum input and claims up to 14:1 turndown, versus the IBC VX 110's 16.9 MBH minimum and up to 6.5:1, so the B2HE can hold low loads without cycling.

Is the VX 110 meaningfully lighter?

Yes: 67 lb (30.4 kg) versus 108 lb (49 kg), which can simplify wall mounting in a tight retrofit mechanical room.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate