IBC VX 110
The IBC VX 110 is the smallest VX Series boiler: 16.9 to 110 MBH input, 95% AFUE, wall-hung on the V-10 controller, with 2" venting allowed to 100 feet and 3" to 240 feet per side.
Key figures
- Max input
- 110 MBH
- Max CSA output
- 101.5 MBH
- AFUE
- 95 %
- Min input
- 16.9 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
IBC VX 110 in practice
The VX 110 sits close to the SL 14-115 G3 in output, but IBC positions the VX line as the more compact option with up to 6.5:1 turndown, built-in multi-zone pump control and a lower shipping weight of 67 lb. For a retrofit where the boiler hangs in a tight mechanical room, that can make installation simpler.
It is heating-only. Domestic hot water comes from an indirect tank that IBC documents connecting directly to the boiler without a primary loop, and the boiler's controller can also drive several heating zones directly, reducing external controls.
Venting flexibility is a strength of this model: up to 100 equivalent feet in 2" or 240 in 3" per side. At 50 psig maximum operating pressure the VX 110 and VX 150 are also rated above the 30 psig of the larger VX 199.
Best suited to
- Detached homes and townhouses whose heat loss fits within 110 MBH
- Retrofits with tight wall space or short vent runs where 2" venting helps
- Projects wanting multi-zone pump control without extra external controllers
Applicability and support
- Model number
- IBGFSW1-0110
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by IBC Technologies. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 16.9 MBH | 5 kW |
| Input, maximum | 110 MBH | 32.2 kW |
| Output | ||
| CSA output, minimum | 16.2 MBH | 4.74 kW |
| CSA output, maximum | 101.5 MBH | 29.8 kW. DOE heating capacity is not published on the IBC pages we cite. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | As published by IBC on the Canadian VX model page. |
| Domestic hot water | ||
| Domestic hot water | Not a combi; IBC documents direct connection of an indirect tank | |
| Venting and air | ||
| Flue material | 3" Schedule 40 or 3" PPs (80 mm); PVC/CPVC/PPs approved | |
| Max. equivalent vent length, 3" | 240 ft | Each side; see the installation manual for the equivalent-length method. |
| Max. equivalent vent length, 2" | 100 ft | |
| Air intake | Direct vent or indoor supply | |
| Physical and connections | ||
| Weight (empty) | 67 lb | 30.4 kg |
| Water connections | 1" NPT | |
| Gas connection | 1/2" NPT | |
| Condensate connection | 3/4" hose | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Conversion kit included per IBC model page. |
| Turndown ratio | up to 6.5:1 | |
| Gas supply pressure | 4 – 14 in. w.c. | |
| Max. operating pressure | 50 psig | Ships with a 30 psig relief valve. |
| Max. water temperature | 190 °F | Electronic limit. |
| Altitude rating | 0 – 12,000 ft | |
Manuals
Alerts documented for this model
- Error – Ignition trials exceeded
- Error – Water High-Limit
- Error – Low Water Cutoff
- Error: Interlock [1 or 2] Open
- Error: Vent High Limit
- Error – Max. delta T Exceeded
- Error – Low RPM / Air Flow
- Error – Fan Pressure
- Error – Module High Current
- Error – Low Module Current
- Error – Low Water Pressure
- Error – Inlet Pres. Sensor
- Error – See: Status > SIM menu > Status
- Error – Roll Out Switch
- Error – Controller Board
- Error – No Boilernet Comm
- Error – No MAC address
- Error – Flame Signal / Vent Block
- Error – Reversed Flow
- Error – Temp. probe error
- Error – Unhandled error code
- Outlet Limited
- Remote offline
- Unoccupied
- Summer
- Failsafe Setpoint
Frequently asked questions
How does the VX 110 compare with the SL 14-115 G3?
Both are heating-only IBC condensing boilers around 110-115 MBH on the same V-10 controller. The VX 110 is lighter (67 lb vs 85 lb) and allows 2" venting, while the SL 14-115 G3 has a lower 14 MBH minimum input versus 16.9 MBH on the VX 110.
Does the VX 110 need a pump for every zone?
IBC's VX page says the boiler has built-in control for up to four zones plus the primary load, which can replace external pump relays. An assessment confirms the wiring and hydronic design for a specific home.
Is the VX 110 available in Canada?
Yes. IBC Canada lists the VX 110 with CSA input and output figures. Whether ROMA supplies it is confirmed at consultation.
Questions about the IBC VX 110?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- IBC VX 110 / VX 150 / VX 199 — model page · accessed September 7, 2026
- IBC VX Series — series page · accessed September 7, 2026
- IBC VX Installation & Operating Manual · 120-347E6 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.