Ideal Exalt Wall Combi 155 vs 199

Verdict in brief

The two Exalt Wall combi models share the 21.75 x 33 x 16.5 inch cabinet, 95% AFUE and 8:1 turndown, but the 199 delivers more of everything: 199,000 vs 155,000 BTU/h heating input and 5.3 vs 4.0 GPM of on-demand DHW at a 70°F rise. The 155 is the only one that lists 2-inch venting (33 ft); the 199 vents with 3-inch pipe up to 100 ft.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Ideal Exalt Wall Combi 155 and Ideal Exalt Wall Combi 199
SpecificationIdeal Exalt Wall Combi 155Ideal Exalt Wall Combi 199
Input, minimum (NG & LP)19.375 MBH24.875 MBH
Input, maximum (NG & LP)155 MBH199 MBH
Efficiency (AFUE)95 %95 %
Turndown ratio8:18:1
DOE heating capacity142 MBH184 MBH
AHRI net rating123 MBH159 MBH
DHW output at 70°F rise4 GPM5.3 GPM
DHW minimum flow rate0.5 GPM0.5 GPM
Weight110 lb128 lb
Domestic hot waterCombi: on-demand DHW via an integrated plate heat exchangerCombi: on-demand DHW via an integrated plate heat exchanger

What actually separates them

Both combis heat the building and produce domestic hot water on demand through an integrated plate heat exchanger. The heating ranges are 19,375 to 155,000 BTU/h on the combi 155 and 24,875 to 199,000 BTU/h on the combi 199, both at 95% AFUE with an 8:1 turndown. DOE heating capacity steps from 142 to 184 MBH and the AHRI net rating from 123 to 159 MBH.

Hot-water delivery is the real divider: 4.0 GPM at a 70°F rise on the 155 against 5.3 GPM on the 199, with 3.7 vs 4.9 GPM at 75°F and 3.5 vs 4.6 GPM at 80°F. Both list a 0.5 GPM minimum flow, a 150 psi maximum DHW pressure and a 150°F (65°C) DHW temperature ceiling.

The cabinet is identical at 21.75 x 33 x 16.5 inches, with weight rising from 110 to 128 lb and water volume from 3 to 4 gallons. Venting differs: the 155 lists 2-inch up to 33 feet and 3-inch up to 100 feet, while the 199 lists 3-inch up to 100 feet only. Both use CTRLMax with DHW priority and plain-text diagnostics, and both ship in natural-gas and propane versions.

CurrentCanadian status unknown
Input
19.375–155 MBH
Output (max)
AFUE
95 %

The Ideal Exalt Wall Combi 155 is a wall-hung combi boiler: 19,375 to 155,000 BTU/h heating input at 95% AFUE with on-demand DHW at 4.0 GPM at a 70°F rise, in a 110 lb cabinet with 2-inch venting up to 33 feet.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
24.875–199 MBH
Output (max)
AFUE
95 %

The Ideal Exalt Wall Combi 199 is the larger wall-hung combi: 24,875 to 199,000 BTU/h heating input at 95% AFUE with on-demand DHW at 5.3 GPM at a 70°F rise and 3-inch venting up to 100 feet.

Natural gasPropaneCombi

Frequently asked questions

Which combi delivers more hot water?

The combi 199, at 5.3 GPM at a 70°F rise against 4.0 GPM for the combi 155, per the official model table.

Do both combis use the same cabinet?

Yes — 21.75 x 33 x 16.5 inches; the 199 weighs 128 lb against 110 lb and holds 4 gallons against 3.

Can the combi 199 use 2-inch venting?

No. The 2-inch vent option (33 ft) is published for the combi 155; the combi 199 lists 3-inch venting up to 100 equivalent feet.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate