Skip to content
Boilers.caby ROMA Heating & Cooling

Ideal Heating · Exalt Wall Combi

Ideal Exalt Wall Combi 155

The Ideal Exalt Wall Combi 155 is a wall-hung combi boiler: 19,375 to 155,000 BTU/h heating input at 95% AFUE with on-demand DHW at 4.0 GPM at a 70°F rise, in a 110 lb cabinet with 2-inch venting up to 33 feet.

CurrentCanadian status unknown

Key figures

Max input
155 MBH
Max CSA output
AFUE
95 %
Min input
19.375 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Ideal Exalt Wall Combi 155 in practice

The Exalt Wall Combi 155 heats and supplies domestic hot water from one wall-hung appliance. Heating input runs 19,375 to 155,000 BTU/h at 95% AFUE with an 8:1 turndown, a 142 MBH DOE heating capacity and a 123 MBH AHRI net rating. The domestic side is documented at 4.0 GPM at a 70°F rise, 3.7 GPM at 75°F and 3.5 GPM at 80°F, with a 0.5 GPM minimum flow, a 150 psi maximum DHW pressure and a 150°F (65°C) DHW temperature ceiling.

The combi cabinet is taller than the heat-only models at 21.75 x 33 x 16.5 inches and weighs 110 lb, holding 3 gallons. It connects with 3/4-inch gas, 1-inch heating supply/return and 3/4-inch DHW inlets and outlets. Venting is 2-inch up to 33 equivalent feet or 3-inch up to 100 feet, through the same 3-in-1 universal vent adapter used across the Exalt Wall family.

The CTRLMax control includes DHW priority with an optional time-out, outdoor reset and plain-text diagnostics. For townhouses and compact homes the combi replaces the traditional boiler-and-tank pair; households whose simultaneous hot-water demand exceeds the published 4.0 GPM figure step up to the combi 199. Natural-gas (IDEX155C) and propane (IDEX155CLP) versions are published. No explicit Canadian sales statement was found on the official pages checked on 2026-09-09; the Exalt and Gallant submittals list ANSI Z21.13 and CSA 4.9 compliance, so Boilers.ca records canadianStatus as unknown.

Best suited to

  • Townhouses, suites and compact detached homes wanting one appliance for heat and hot water
  • Households whose simultaneous DHW demand stays within about 4.0 GPM at a 70°F rise
  • Installations that can use 2-inch venting up to 33 feet

Applicability and support

Model number
IDEX155C (NG) / IDEX155CLP (LP)
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Ideal Heating. Units are shown with every value; notes flag conflicting sources or missing figures.

Ideal Exalt Wall Combi 155 specifications
SpecificationValueNote
Input
Input, minimum (NG & LP)19.375 MBH19,375 BTU/h per the official model table
Input, maximum (NG & LP)155 MBH155,000 BTU/h per the official model table
Output
DOE heating capacity142 MBHPer the official model table.
AHRI net rating123 MBHPer the official model table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the official model table.
Domestic hot water
DHW output at 70°F rise4 GPMPer the official model table.
DHW output at 75°F rise3.7 GPMPer the official model table.
DHW output at 80°F rise3.5 GPMPer the official model table.
DHW minimum flow rate0.5 GPMPer the official model table.
DHW maximum operating pressure150 psiPer the official model table.
Domestic inlet / outlet connections3/4 in
Maximum DHW flow temperature150 °F150°F (65°C) per the official model table.
Domestic hot waterCombi: on-demand DHW via an integrated plate heat exchanger
Venting and air
Vent / air connections3 in
Maximum vent length, 3 in100 ftPer the official model table.
Maximum vent length, 2 in33 ftPer the official model table.
Physical and connections
Weight110 lb
Width21.75 in
Height33 in
Depth16.5 in
Operating limits and other
Turndown ratio8:1Per the official model table.
Gas connection (MNPT)3/4 in
Supply / return connections (MNPT)1 in
Water volume3 galPer the official model table.
Maximum CH flow temperature185 °F185°F (85°C) per the official model table.

Frequently asked questions

How much hot water does the Exalt Wall Combi 155 deliver?

4.0 GPM at a 70°F rise, 3.7 GPM at 75°F and 3.5 GPM at 80°F, with a 0.5 GPM minimum flow rate and a 150 psi maximum DHW operating pressure.

What is the heating range of the Exalt Wall Combi 155?

19,375 to 155,000 BTU/h input at 95% AFUE with an 8:1 turndown, a 142 MBH DOE heating capacity and a 123 MBH AHRI net rating.

Can the Exalt Wall Combi 155 run on propane?

Yes — the model ships as IDEX155C (natural gas) or IDEX155CLP (propane), and conversion instructions both ways are published in the installation manual set.

Questions about the Ideal Exalt Wall Combi 155?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate