Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Rinnai IP090099C vs IP090199C

Verdict in brief

The IP090099C and IP090199C share the same 90 MBH heating input, 73 lb chassis and 15 MBH minimum fire, and differ almost entirely on the hot-water side: the 199 model fires DHW to 199 MBH (versus 99) and flows 7.9 GPM (versus 5.3), which is why its 2" vent allowance disappears in favour of a 160 ft 3" run.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Rinnai IP090099C and Rinnai IP090199C
SpecificationRinnai IP090099CRinnai IP090199C
Heating input, minimum15 MBH15 MBH
Heating input, maximum90 MBH90 MBH
DHW input, maximum99 MBH199 MBH
Maximum DHW flow rate5.3 GPM7.9 GPM
Efficiency (AFUE)96 %96 %
Weight73 lb73 lb
Water content (CH)0.75 gal0.75 gal
Max. equivalent vent length, 2"100 ft—
Max. equivalent vent length, 3"—160 ft

What actually separates them

Both models are 90 MBH heating combis at 73.0 lb in the small chassis with a 15 MBH minimum fire, 0.75 gal of CH water and the same connections — the 090 prefix is literally the same heating rating. Everything that differs is on the domestic hot water side or follows from it.

The IP090199C doubles the DHW input to 199 MBH and lifts maximum flow to 7.9 GPM per the I&O manual — the same manual that prints 99 MBH and 5.3 GPM for the IP090099C. The rinnai.ca product page for the IP090199C prints 9.8 GPM and 68 lb, both of which conflict with the manual and are flagged on the model record rather than repeated.

Venting is where the larger DHW rating changes the install: the manual's vent table prints no 2" length for the IP090199C but puts it in the 160-ft 3" row group, whereas the IP090099C keeps a 100 ft 2" allowance below 2,000 ft elevation.

CurrentSold in Canada
Input
15–90 MBH
Output (max)
—
AFUE
96 %

The Rinnai IP090099C is the I-Series+ combi with the closest CH/DHW pair: 15 to 90 MBH heating input and a 99 MBH DHW input (5.3 GPM maximum flow), rated up to 96% AFUE in Rinnai's Canadian marketing.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–90 MBH
Output (max)
—
AFUE
96 %

The Rinnai IP090199C pairs a 90 MBH heating input with a 199 MBH DHW input: 15 to 90 MBH central heating plus near-tankless hot-water headroom in the small 73 lb chassis, rated up to 96% AFUE in Rinnai's Canadian marketing.

Natural gasPropaneCombi

Frequently asked questions

Are the two boilers the same weight?

Per the I&O manual, yes — 73.0 lb (33 kg) for both. The IP090199C product page prints 68 lb, a documented page/manual discrepancy.

Why does the IP090199C flow less than its product page says?

The manual spec table prints 7.9 GPM (30 L/min) while the rinnai.ca page prints 9.8 GPM. Boilers.ca uses the manual figure and documents the conflict.

When is the IP090099C the better choice?

When the heating load is near 90 MBH and hot-water demand is ordinary — the 099C keeps a 100 ft 2" vent option and a smaller DHW gas draw, while the 199C buys hot-water headroom at 199 MBH.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate