Rinnai · i-Series+ Combi

Rinnai IP090099C

The Rinnai IP090099C is the I-Series+ combi with the closest CH/DHW pair: 15 to 90 MBH heating input and a 99 MBH DHW input (5.3 GPM maximum flow), rated up to 96% AFUE in Rinnai's Canadian marketing.

CurrentSold in Canada

Key figures

Max input
90 MBH
Max CSA output
—
AFUE
96 %
Min input
15 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Rinnai IP090099C in practice

The IP090099C is unusual in the I-Series+ combi range because its two ratings are nearly equal: up to 90,000 BTU/h for central heating and 99,000 BTU/h for domestic hot water, with 5.3 GPM maximum DHW flow per the I&O manual. It is the only small combi whose DHW side does not far exceed the heating side, which keeps its gas supply and venting demand modest.

Like the rest of the small chassis, it weighs 73 lb, holds 0.75 gal of CH water and mounts on an 18.5 x 11.5 in footprint. Its 2" twin-pipe vent allowance is the longest in the small-combi group at 100 equivalent feet below 2,000 ft elevation (75 ft above), per the I&O manual Table 20.

All small-combi supply connections apply — 3/4" NPT gas and DHW, 1" NPT heating — and CH water pressure is 13-45 PSI with a 30 PSI relief valve included. Efficiency is the family marketing claim of up to 96% AFUE; the manual prints no per-model AFUE figure.

Best suited to

  • Homes whose heat loss and hot-water needs both sit near 90-100 MBH
  • Owners who want a combi without the gas-demand jump of a 199 MBH DHW rating
  • Longer 2" vent runs up to 100 equivalent ft below 2,000 ft elevation

Applicability and support

Model number
IP090099C
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.

Rinnai IP090099C specifications
SpecificationValueNote
Input
Heating input, minimum15 MBHSpace-heating input; 15,000 BTU/h minimum input per spec Table 2.
Heating input, maximum90 MBHSpace-heating (CH) maximum input per spec Table 2.
Efficiency
Efficiency (AFUE)96 %Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables.
Domestic hot water
DHW input, maximum99 MBH99,000 BTU/h maximum DHW input per spec Table 2.
Maximum DHW flow rate5.3 GPM5.3 GPM (20 L/min) per spec Table 2; 2.5 GPM at a 70°F rise. The product page lists 5.3 GPM.
Domestic hot waterOn demand inside the combiDHW input and flow figures above; DHW temperature setting range 98°F-140°F (37°C-60°C) per spec Table 2.
Venting and air
Venting2" nominal PVC/polypropylene or 3" x 5" concentricVent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section.
Max. equivalent vent length, 2"100 ftTwin-pipe 2" PVC / 2" PP maximum equivalent length per the I&O manual (Table 20); above 2,000 ft (610 m) elevation the maximum drops to 75 ft.
Physical and connections
Weight73 lb73.0 lb (33 kg) per the I&O manual spec Table 2; the product page lists 73 lb (33.11 kg).
Water content (CH)0.75 galCentral-heating water content per spec Table 2.
Gas connection3/4" NPTPer spec Table 3.
Heating water connections1" NPTCH supply and return per spec Table 3.
DHW connections3/4" NPTDHW cold inlet and hot outlet per spec Table 3.
Width18.5 in (470 mm)Per the I&O manual dimension figure and the product page.
Depth11.5 in (291 mm)Per the I&O manual dimension figure; the product page lists 292.1 mm.
Operating limits and other
FuelNatural gas or propaneGas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa).
CH water pressure13 – 45 psiMinimum 13 PSI (90 kPa), maximum 45 PSI (310 kPa); recommended 17-26 PSI; 30 PSI pressure relief valve included with the system (spec Table 2).

Frequently asked questions

Why does the IP090099C deliver less hot water than the IP060160C?

Its DHW rating is smaller by design: 99,000 BTU/h of DHW input and 5.3 GPM maximum flow against the IP060160C's 160,000 BTU/h and 7.9 GPM. Both figures come from the I&O manual spec table.

Does the IP090099C vent in 2" pipe?

Yes — and further than the other small combis: the I&O manual allows 100 equivalent feet in 2" twin-pipe below 2,000 ft elevation, dropping to 75 ft above that elevation.

How do I read the 090099 part of the model name?

As CH input over DHW input in thousands of BTU/h: 90 MBH of central-heating input and 99 MBH of DHW input.

Questions about the Rinnai IP090099C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate