Rinnai IP090199C vs IP120199C

Verdict in brief

Stepping from the IP090199C to the IP120199C raises central-heating input from 90 to 120 MBH and maximum DHW flow from 7.9 to 9.8 GPM, but the larger unit moves to the bigger small-chassis heat exchanger: 76.1 lb and 0.88 gal of water versus 73.0 lb and 0.75 gal, and it regains a 2" vent option (75 ft) alongside the shared 160 ft 3" allowance.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Rinnai IP090199C and Rinnai IP120199C
SpecificationRinnai IP090199CRinnai IP120199C
Heating input, minimum15 MBH15 MBH
Heating input, maximum90 MBH120 MBH
DHW input, maximum199 MBH199 MBH
Maximum DHW flow rate7.9 GPM9.8 GPM
Efficiency (AFUE)96 %96 %
Weight73 lb76.1 lb
Water content (CH)0.75 gal0.88 gal
Max. equivalent vent length, 2"—75 ft
Max. equivalent vent length, 3"160 ft160 ft

What actually separates them

Both boilers carry the full 199 MBH DHW rating, so the step between them is about the heating side and the hardware that supports it. The IP120199C fires 30 MBH higher for central heating (120 versus 90 MBH) and delivers 9.8 GPM maximum DHW flow against the IP090199C's 7.9 GPM per the manual.

The hardware difference is visible in the specs: the manual puts the 120 model on the 10.9 sq ft heat exchanger with 0.88 gal of CH water at 76.1 lb, while the 90 model stays on the 9.3 sq ft unit at 73.0 lb with 0.75 gal. The rinnai.ca pages print 62 lb for the 120 model — a documented discrepancy with the manual's 76.1 lb.

Venting is cleaner on the 120: the manual prints both a 75 ft 2" option and the 160 ft 3" row for it, whereas the IP090199C has no printed 2" length and relies on 3" to 160 ft.

CurrentSold in Canada
Input
15–90 MBH
Output (max)
—
AFUE
96 %

The Rinnai IP090199C pairs a 90 MBH heating input with a 199 MBH DHW input: 15 to 90 MBH central heating plus near-tankless hot-water headroom in the small 73 lb chassis, rated up to 96% AFUE in Rinnai's Canadian marketing.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–120 MBH
Output (max)
—
AFUE
96 %

The Rinnai IP120199C lifts heating to 120 MBH of input while keeping the 199 MBH DHW side: 15 to 120 MBH central heating with 9.8 GPM maximum hot-water flow, in the heavier 76.1 lb small chassis.

Natural gasPropaneCombi

Frequently asked questions

Do both models have the same DHW rating?

Yes, both fire DHW to 199 MBH, but maximum flow differs: 9.8 GPM on the IP120199C versus 7.9 GPM on the IP090199C per the I&O manual.

Which model is heavier?

The IP120199C: 76.1 lb (34.5 kg) versus 73.0 lb (33 kg) per the manual. The 120's product page prints 62 lb, which Boilers.ca flags as a discrepancy.

When should I choose the IP090199C instead?

When the heat-loss calculation stays below the 120's reach and the DHW demand fits 7.9 GPM — the 90 model is lighter and does not need the 10.9 sq ft heat exchanger.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate