Laars NTH150 vs NTH210

Verdict in brief

The NTH150 and NTH210 are the middle and upper steps of the NeoTherm Residential ladder — the 150 and 210 columns of Document 1252K — the same modulating condensing boiler with shared Hold/Lockout diagnostics, differing in size and the heavier blower, heat exchanger and gas train of the larger column.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Laars NTH150 and Laars NTH210
SpecificationLaars NTH150Laars NTH210
Maximum input (as printed)150 MBH210 MBH
FuelNatural gas or propaneNatural gas or propane
Domestic hot waterBoiler model — the control's error table includes DHW high-limit (80) and DHW sensor (93) entries per Appendix BBoiler model — the control's error table includes DHW high-limit (80) and DHW sensor (93) entries per Appendix B
Error reportingNumeric codes reported as Hold (H) or Lockout (L) — Appendix B of the I&O manual (Document 1252K) and Appendix 1 of the service manual (Document 1291)Numeric codes reported as Hold (H) or Lockout (L) — Appendix B of the I&O manual (Document 1252K) and Appendix 1 of the service manual (Document 1291)

What actually separates them

The parts list in Document 1252K separates the line into assemblies that scale with size — the NTH210 column starts sharing its blower, heat exchanger and gas-valve parts with the top NTH285 rather than the smaller models — but the operator interface and diagnostics remain identical across the series.

Both models report numeric Holds and Lockouts from the shared tables, support the lead-lag menus for multiple-boiler plants, and keep the factory 195°F dual-thermistor high-limit arrangement described in the manual's sensor chapter. The service manual, Document 1291, applies to both.

The step from 150 to 210 exists for loads in between: a building whose heat-loss calculation crosses the 150 column on a design day, or that pairs the boiler with NTV water-heating duty at the 210 scale, is where the NTH210 earns its place.

Laars Heating Systems

Laars NTH150

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars NTH150 is the mid-size NeoTherm Residential boiler: a floor-standing modulating condensing unit at the 150 step of the 080-285 MBTU/h range, on the numeric Hold/Lockout code system of Document 1252K.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars NTH210

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars NTH210 is the second-largest NeoTherm Residential boiler: a floor-standing modulating condensing unit at the 210 step of the 080-285 MBTU/h range, on the numeric Hold/Lockout code system of Document 1252K.

Natural gasPropaneHeating-only

Frequently asked questions

Do the NTH150 and NTH210 share parts?

Some assemblies scale with the size — the parts list shows the NTH210 and NTH285 sharing blower, heat-exchanger and gas-train components that differ from the smaller columns — while jacket and control parts are common.

Can either model run in a multi-boiler plant?

Yes. The manual documents lead-lag configuration (LL Master and LL Follower options with equal-run-time sequencing), so NTH models including the 150 and 210 can be staged together.

What is the NTH code source for both models?

Appendix B of the I&O manual (Document 1252K, page 72) and Appendix 1 of the service manual (Document 1291), both of which cover the full 080-285 range.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate