Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Lochinvar Copper-Fin Fan Assisted CBN0497 vs Copper-Fin II CHN0402

Verdict in brief

The fan-assisted CBN0497 and Copper-Fin II CHN0402 are the entry sizes of their lines: the CBN0497 reaches 495 MBH at 84% with two-stage firing and an 8"-class footprint, while the CHN0402 reaches 399 MBH at 85% with proportional firing up to 4:1 and the SMART SYSTEM control with 8-boiler cascade.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Copper-Fin Fan Assisted CBN0497 and Lochinvar Copper-Fin II CHN0402
SpecificationLochinvar Copper-Fin Fan Assisted CBN0497Lochinvar Copper-Fin II CHN0402
Heating input, minimum250 MBH250 MBH
Heating input, maximum495 MBH399 MBH
Gross output416 MBH339 MBH
Net AHRI water rating362 MBH295 MBH
Efficiency (thermal)84 %85 %
Water content1.9 gal1.8 gal
Space-heating water connections2"2"
Gas connection1-1/4"1-1/4"
Air inlet size—6"
Vent size6"6"
FiringTwo-stage (high/low fire)Proportional, up to 4:1 turndown
Shipping weight440 lb378 lb

What actually separates them

The CBN0497 covers 250 to 495 MBH input with 416 MBH gross output and a 362 MBH AHRI net rating at 84% thermal efficiency; the CHN0402 covers 250 to 399 MBH input with 339 MBH gross output and a 295 MBH AHRI net rating at 85%. The fan-assisted model carries about 96 MBH more ceiling at one point less efficiency.

The bigger difference is the control: the CHN0402 uses the SMART SYSTEM operating control with a 2-line/16-character LCD, a built-in cascading sequencer for up to 8 boilers, front-end loading with Crest or Knight, BMS integration and 0-10 VDC rate output, and fires proportionally up to 4:1. The CBN0497 uses a two-stage electronic temperature control with diagnostic lights.

Both are fan-assisted Category I designs with sealed combustion chambers and hot surface ignition, and both vent through 6" pipe with 6" air. The CHN0402's submittal additionally lists Category IV AL29-4C stainless venting and DirectAire/powered sidewall options, and it weighs 378 lb against the CBN0497's 440 lb.

CurrentSold in Canada
Input
250–399 MBH
Output (max)
—
AFUE
—

The Copper-Fin II CHN0402 opens the line at 250 to 399 MBH input with 339 MBH gross output and a 295 MBH AHRI net rating at 85% thermal efficiency, with the SMART SYSTEM control and up to 4:1 proportional firing.

Natural gasPropaneHeating-only

Frequently asked questions

Which model has more capacity?

The fan-assisted CBN0497, at 495 MBH maximum input and 416 MBH gross output, against 399 MBH and 339 MBH on the CHN0402.

Which model has the more capable control?

The Copper-Fin II CHN0402: it carries the SMART SYSTEM control with an 8-boiler cascading sequencer, BMS integration and 0-10 VDC rate output, plus proportional firing up to 4:1.

Do both support Category IV venting?

No. The CHE-Sub-11 submittal lists Category I Type B and Category IV AL29-4C venting for the CHN0402; the fan-assisted CBN0497 is a Category I unit with conventional negative-draft or outdoor installation venting.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate