Skip to content
Boilers.caby ROMA Heating & Cooling

Lochinvar · Copper-Fin (CBN/CHN)

Lochinvar Copper-Fin II CHN0402

The Copper-Fin II CHN0402 opens the line at 250 to 399 MBH input with 339 MBH gross output and a 295 MBH AHRI net rating at 85% thermal efficiency, with the SMART SYSTEM control and up to 4:1 proportional firing.

CurrentSold in Canada

Key figures

Max input
399 MBH
Max CSA output
—
AFUE
—
Min input
250 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Copper-Fin II CHN0402 in practice

The CHN0402 is the smallest of the nine Copper-Fin II sizes and the model whose page represents the line on lochinvar.com. The I&O ratings table lists 250 to 399 MBH input, 339 MBH gross output and a 295 MBH AHRI net water rating at 85% thermal efficiency, with 1.8 gallons of water content; the CHE-Sub-11 submittal prints a 378 lb shipping weight, 6" vent and 6" air inlet on 2" NPT water and 1-1/4" gas connections.

The line's page headlines "9 Models from 399,000 to 2,070,000 Btu/hr," "85% Thermal Efficiency," "Up to 4:1 Proportional Firing" and the SMART SYSTEM operating control with a built-in cascading sequencer for up to 8 boilers. Copper-Fin II is certified to ANSI Z21.13/CSA 4.9 and vents as Category I Type B or Category IV AL29-4C stainless steel, vertically or horizontally, with DirectAire and powered sidewall options. The submittal prints 85% thermal efficiency (AHRI certified), a 10-year limited warranty and 1-year parts.

Best suited to

  • Commercial loads near 400 MBH that want proportional firing rather than two-stage
  • Plants planning a cascade of up to 8 Copper-Fin II boilers
  • Projects that want Category IV stainless venting options at the smallest size

Applicability and support

Model number
CHN0402
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Copper-Fin II CHN0402 specifications
SpecificationValueNote
Input
Heating input, minimum250 MBHPer the I&O ratings table.
Heating input, maximum399 MBHPer the submittal sheet and the I&O ratings table.
Output
Gross output339 MBHGross output per the submittal sheet ratings table.
Net AHRI water rating295 MBHNet AHRI rating based on a piping and pickup allowance of 1.15, per the submittal and I&O ratings-table notes.
Efficiency
Efficiency (thermal)85 %85% thermal efficiency (AHRI certified) printed in the CHE-Sub-11 submittal and on the product page; no AFUE is published.
Venting and air
Vent size6"Per the submittal and I&O ratings tables.
Air inlet size6"Per the CHE-Sub-11 submittal ratings table.
VentingCategory I (Type B double-wall) or Category IV (AL29-4C stainless steel); vertical or horizontalPer the CHE-Sub-11 standard features and the CHX I&O venting section; DirectAire and powered sidewall options are listed in the submittal.
Physical and connections
Water content1.8 galPer the I&O ratings table.
Space-heating water connections2"2" NPT on 6-1/2" centers per the CHE-Sub-11 submittal.
Gas connection1-1/4"Per the submittal and I&O ratings tables.
Shipping weight378 lbShipping weight per the submittal sheet ratings table.
Dimension A31-1/2"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension B37-3/4"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension C22-1/4"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension D12-1/2"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension E7"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension F7"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension G29"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension H6-1/2"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Operating limits and other
FiringProportional, up to 4:1 turndownProportional firing up to 4:1 turndown per the CHE-Sub-11 standard features; the CHX I&O ratings table prints minimum inputs of 250/360/630 MBH by size.

Manuals

    Alerts documented for this model

    None documented yet.

    Services

    Frequently asked questions

    What are the CHN0402's ratings?

    250 to 399 MBH input, 339 MBH gross output and a 295 MBH AHRI net water rating at 85% thermal efficiency, per the CHE-Sub-11 submittal and the CHX I&O ratings table.

    What control does the CHN0402 use?

    The SMART SYSTEM operating control with a 2-line/16-character LCD, a built-in cascading sequencer for up to 8 boilers, BMS integration and 0-10 VDC rate output, per the CHE-Sub-11 standard features.

    Questions about the Lochinvar Copper-Fin II CHN0402?

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate