Verdict in brief

The atmospheric CBN500 and fan-assisted CBN0497 are the adjacent sizes where Lochinvar's Copper-Fin lines hand off: both land near 500 MBH of input (500 vs 495), but the CBN500 is 82.0% thermal efficiency with a built-in draft diverter and two-stage firing, while the CBN0497 is 84% with fan-assisted sealed combustion and a 6" vent instead of 10".

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Copper-Fin Atmospheric CBN500 and Lochinvar Copper-Fin Fan Assisted CBN0497
SpecificationLochinvar Copper-Fin Atmospheric CBN500Lochinvar Copper-Fin Fan Assisted CBN0497
Heating input, minimum250 MBH250 MBH
Heating input, maximum500 MBH495 MBH
Gross output410 MBH416 MBH
Net AHRI water rating357 MBH362 MBH
Efficiency (thermal)82 %84 %
Water content1.4 gal1.9 gal
Space-heating water connections2"2"
Gas connection1"1-1/4"
air-inlet-size
Vent size10"6"
FiringTwo-stage (high/low fire)Two-stage (high/low fire)
Shipping weight345 lb440 lb

What actually separates them

The two boilers cover almost the same load: 250 to 500 MBH input on the CBN500 against 250 to 495 MBH on the CBN0497, with gross outputs of 410 and 416 MBH and AHRI net ratings of 357 and 362 MBH. A heat-loss calculation decides between them, not the ceiling.

The engineering difference is combustion and venting. The CBN500 is a conventional negative-draft Category I boiler with a built-in draft diverter and a 10" Type B vent; the CBN0497 is a fan-assisted Category I unit with a sealed combustion chamber and a 6" vent, so it can use outdoor installation venting and fits through a standard 36" doorway.

Efficiency and connections also split: 82.0% thermal on the CBN500 versus 84% on the CBN0497, with both on 2" NPT water connections and a 1" versus 1-1/4" gas connection. Firing stays two-stage high/low on both, and the submittals print 10-year heat-exchanger warranties.

Frequently asked questions

Which of these two boilers is more efficient?

The fan-assisted CBN0497 at 84% thermal efficiency, against 82.0% for the atmospheric CBN500.

Why does the CBN0497 use a smaller vent?

It is fan-assisted with a sealed combustion chamber, so it vents through 6" pipe, while the atmospheric CBN500 is a natural-draft Category I appliance that needs a 10" Type B vent.

Do both fire the same way?

Yes. Both use two-stage high/low firing; the atmospheric line uses a two-stage solid state temperature control and the fan-assisted line a two-stage electronic temperature control.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate