Verdict in brief

The Epic EPC150N and EPC199N are wall combis at 150 and 199 MBH input, both 95% AFUE. The 199 delivers 4.8 gpm of domestic hot water at a 77°F rise versus 3.6 gpm on the 150, with 46 MBH more DOE heating capacity and an identical 3" vent size.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Epic EPC150N and Lochinvar Epic EPC199N
SpecificationLochinvar Epic EPC150NLochinvar Epic EPC199N
Input, minimum15 MBH20 MBH
Input, maximum150 MBH199 MBH
Efficiency (AFUE)95 %95 %
DOE heating capacity139 MBH185 MBH
Net AHRI water rating121 MBH161 MBH
DHW delivery at 77°F rise3.6 GPM4.8 GPM
Gas connection1/2"1/2"
Water connection1"1"
Air inlet size3"3"
Vent size3"3"
Shipping weight132 lb140 lb
Turndown10:110:1

What actually separates them

The EPC-Sub-02 submittal lists the EPC150N at 15-150 MBH input, 139 MBH DOE heating capacity and a 121 MBH net AHRI rating; the EPC199N lists 20-199 MBH input, 185 MBH DOE capacity and a 161 MBH net AHRI rating, both at 95.0% AFUE.

Domestic hot water delivery is the clearest difference: 3.6 gpm at a 77°F rise on the EPC150N versus 4.8 gpm on the EPC199N, per the submittal's DHW delivery table.

Both use a 1/2" gas connection, 1" water connection and 3" air and vent connections, so the choice rests on the home's heating load and hot-water demand.

CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The Lochinvar Epic EPC150N is a wall-mounted combination boiler rated 15-150 MBH input, 139 MBH DOE heating capacity and a 121 MBH net AHRI rating at 95% AFUE and delivers 3.6 gpm of domestic hot water at a 77°F temperature rise.

Natural gasPropaneCombi
CurrentSold in Canada
Input
20–199 MBH
Output (max)
—
AFUE
95 %

The Lochinvar Epic EPC199N is a wall-mounted combination boiler rated 20-199 MBH input, 185 MBH DOE heating capacity and a 161 MBH net AHRI rating at 95% AFUE and delivers 4.8 gpm of domestic hot water at a 77°F temperature rise.

Natural gasPropaneCombi

Frequently asked questions

How much hot water does the EPC199N deliver?

The EPC-Sub-02 submittal prints 4.8 gpm at a 77°F temperature rise for the EPC199N, versus 3.6 gpm for the EPC150N.

Do the EPC150N and EPC199N use the same venting?

Yes — both print 3" air and vent connections in the submittal rating table, with 10:1 turndown.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.