Lochinvar FTXL FTX850 vs FTX1000

Verdict in brief

The FTXL FTX1000 is the Series 110 flagship at 999,000 BTU/hr: against the FTX850 it fires 100 to 1000 MBH at 98.3% submittal thermal efficiency (the line's best) with 10:1 turndown, stepping the gas connection to 1-1/4", the air intake to 6" and the water content to 19 gallons.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar FTXL FTX850 and Lochinvar FTXL FTX1000
SpecificationLochinvar FTXL FTX850Lochinvar FTXL FTX1000
Heating input, minimum121.4 MBH100 MBH
Heating input, maximum850 MBH1,000 MBH
Gross output825 MBH982 MBH
Net AHRI water rating717 MBH854 MBH
Efficiency (thermal)97 %98.3 %
Water content15.9 gal19 gal
Space-heating water connections2-1/2"2-1/2"
Gas connection1"1-1/4"
Air inlet size4"6"
Vent size6"6"
Shipping weight604 lb670 lb

What actually separates them

The FTX850 is a Series 120 unit and the FTX1000 is the Series 110 "FTXL 1.0" — the I&O covers them in separate series groups, and they behave differently at part load: the submittal rates the 850 at 7:1 turndown and the 1000 at 10:1.

The 1000 prints the best efficiency in the line — 98.3% submittal thermal efficiency against the 850's 97.0% — and lifts capacity from 850 to 1000 MBH of input with gross output from 825 to 982 MBH and the AHRI net rating from 717 to 854 MBH.

The plant steps too: the gas connection grows from 1" to 1-1/4", the air intake from 4" to 6", water content from 15.9 to 19 gallons and shipping weight from 604 to 670 lb per the submittal; the vent stays 6".

CurrentSold in Canada
Input
121.4–850 MBH
Output (max)
AFUE

The FTXL FTX850 fires 121.4 to 850 MBH with 825 MBH gross output and a 717 MBH AHRI net rating at 97.0% submittal thermal efficiency, on 2-1/2" water connections with 6" venting.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
100–1000 MBH
Output (max)
AFUE

The FTXL FTX1000 tops the FTXL line at 100 to 1000 MBH input with 982 MBH gross output and an 854 MBH AHRI net rating at 98.3% submittal thermal efficiency — the "FTXL 1.0" 999,000 model.

Natural gasPropaneHeating-only

Frequently asked questions

Why is the FTX1000 rated in a different series?

The FTXL I&O covers "Models 400-850 Series 120 & 1000 Series 110" — the FTX1000 is the Series 110 unit while the 400-850 sizes are Series 120.

Which FTXL has the highest efficiency?

The FTX1000 at 98.3% thermal efficiency per the submittal — higher than the Series 120 sizes, which run from 98.0% (FTX400) down to 97.0% (FTX850).

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate