Lochinvar FTXL FTX1000

The FTXL FTX1000 tops the FTXL line at 100 to 1000 MBH input with 982 MBH gross output and an 854 MBH AHRI net rating at 98.3% submittal thermal efficiency — the "FTXL 1.0" 999,000 model.

CurrentSold in Canada

Key figures

Max input
1,000 MBH
Max CSA output
AFUE
Min input
100 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar FTXL FTX1000 in practice

The FTX1000 is the Series 110 flagship of the FTXL line — Lochinvar's "FTXL 1.0" at 999,000 BTU/hr, the top of the product page's model selector. The I&O ratings table lists 100 to 1000 MBH input with 982 MBH gross output and an 854 MBH AHRI net water rating, and the submittal prints 98.3% thermal efficiency with 10:1 turndown (matching the 100 MBH minimum input).

Water content reaches 19 gallons, connections step to 2-1/2" water and 1-1/4" gas, and air intake and vent are both 6". Venting is in PVC, CPVC, polypropylene or AL29-4C stainless steel to 100 equivalent feet per the submittal, and the submittal lists a 670 lb shipping weight — the heaviest in the FTXL line. The stainless steel fire-tube platform, SMART TOUCH control with CON·X·US and ASME H stamp carry through from the Series 120 sizes.

Best suited to

  • The largest light-commercial loads the FTXL line covers, near 1,000 MBH
  • Plants wanting 10:1 turndown at the top of the FTXL range
  • Projects sized for 2-1/2" water and 1-1/4" gas connections with 6" venting

Applicability and support

Model number
FTX1000N
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar FTXL FTX1000 specifications
SpecificationValueNote
Input
Heating input, minimum100 MBHPer the I&O ratings table.
Heating input, maximum1,000 MBHPer the I&O ratings table.
Output
Gross output982 MBHPer the I&O ratings table.
Net AHRI water rating854 MBHPer the I&O ratings table.
Efficiency
Efficiency (thermal)98.3 %98.3% thermal efficiency per the FTXL submittal.
Venting and air
Air inlet size6"Per the I&O ratings table.
Vent size6"Per the I&O ratings table.
VentingCategory IV sealed combustion; room air/direct vent in PVC, CPVC, polypropylene or AL29-4C stainless steelDirect vent to 100 equivalent feet per the FTXL submittal and the product-page feature list; common vent kit available.
Physical and connections
Water content19 galPer the I&O ratings table.
Space-heating water connections2-1/2"Per the I&O ratings table.
Gas connection1-1/4"Per the I&O ratings table.
Shipping weight670 lbShipping weight per the FTXL submittal.

Frequently asked questions

What are the FTX1000's ratings?

100 to 1000 MBH of input with 982 MBH gross output and an 854 MBH AHRI net water rating at 98.3% thermal efficiency per the FTXL submittal.

Why does the FTX1000 have a different series number?

The I&O manual covers "Models 400-850 Series 120 & 1000 Series 110": the 400-850 sizes are Series 120 and the FTX1000 is the Series 110 unit in the line.

Questions about the Lochinvar FTXL FTX1000?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate