Lochinvar Noble NCF110 vs NCF150

Verdict in brief

The Noble NCF110 and NCF150 are the two smaller floor-standing Noble combis and mirror the wall NKC step: the 150 fires 15 to 150 MBH with 139 MBH of DOE capacity against the 110's 102, and its 2" vent allowance drops from 100 to 60 equivalent feet while connections stay 1" NPT and 3/4" DHW.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Noble NCF110 and Lochinvar Noble NCF150
SpecificationLochinvar Noble NCF110Lochinvar Noble NCF150
Heating input, minimum11 MBH15 MBH
Heating input, maximum110 MBH150 MBH
DOE heating capacity102 MBH139 MBH
AHRI net water rating89 MBH121 MBH
Efficiency (AFUE)95 %95 %
Water content1.4 gal2 gal
Space-heating water connections1" NPT1" NPT
DHW water connections3/4"3/4"
Gas connection1/2"1/2"
Max. equivalent vent/air length, 2"100 ft60 ft
Max. equivalent vent/air length, 3"100 ft100 ft
Domestic hot waterOn demand from the combi's DHW circuitOn demand from the combi's DHW circuit

What actually separates them

Both NCF models are floor-standing Noble combis producing domestic hot water on demand through 3/4" DHW connections, with 1" NPT space-heating connections, a 1/2" gas connection and 95.0% AFUE — the floor counterparts of the NKC110 and NKC150 ratings.

The NCF110 page quotes DHW of up to 2.6 GPM at a 77°F rise, and the NCF150's spec format does not print a DHW flow, so the step between them is best read as heating capacity: DOE output rises from 102 to 139 MBH.

Venting follows the wall combis: the 110 allows 2" pipe to 100 equivalent feet and the 150 only to 60, with 3" at 100 feet on both. Water content grows from 1.4 to 2.0 gallons on the larger model.

CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The Noble NCF110 is the entry Noble floor-standing combi: 11 to 110 MBH input at 95.0% AFUE, rated for DHW of up to 2.6 GPM at a 77°F rise, on a 290 lb floor cabinet.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The Noble NCF150 is the 150 MBH floor-standing Noble combi: 15 to 150 MBH input at 95.0% AFUE with 139 MBH DOE capacity and on-demand DHW through 3/4" connections.

Natural gasPropaneCombi

Frequently asked questions

How does the NCF150 differ from the NCF110?

Input rises from 11-110 MBH to 15-150 MBH, DOE capacity from 102 to 139 MBH and water content from 1.4 to 2.0 gallons; the 2" vent allowance shortens from 100 to 60 equivalent feet.

Are the NCF combis the same as the NKC combis?

In ratings and connections, yes — the NCF models are the floor-standing versions of the wall-mounted NKC combis, sharing the Noble ratings rows in the I&O manual.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.