Lochinvar · Noble Fire Tube (NKB/NKC/NCF)
Lochinvar Noble NCF150
The Noble NCF150 is the 150 MBH floor-standing Noble combi: 15 to 150 MBH input at 95.0% AFUE with 139 MBH DOE capacity and on-demand DHW through 3/4" connections.
Key figures
- Max input
- 150 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 15 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Lochinvar Noble NCF150 in practice
The NCF150 is the floor-standing combi of the Noble 150 ratings row: 15 to 150 MBH of space-heating input with 139 MBH of DOE heating capacity and a 121 MBH AHRI net rating at 95.0% AFUE. It pairs the floor-mount form factor with the combi's on-demand domestic hot water, which its NKC150 wall counterpart also provides.
Connections follow the combi pattern — 1" NPT space heating, 3/4" DHW and a 1/2" gas connection — with a 2.0-gallon water content. Venting allows 2" to 60 equivalent feet or 3" to 100 at the 150 size, and the SMART CONTROL's text-name fault reporting and DHW diverter logic are shared across the Noble combis that Lochinvar sells as Epic in Canada.
Best suited to
- Homes with loads between 110 and 150 MBH wanting a floor combi
- Basement plants combining one appliance for heat and hot water
- Projects with 3" vent routes to 100 equivalent feet
Applicability and support
- Model number
- NCF150L
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 15 MBH | Per the I&O ratings table. |
| Heating input, maximum | 150 MBH | Per the I&O ratings table. |
| Output | ||
| DOE heating capacity | 139 MBH | DOE heating capacity per the I&O ratings table. |
| AHRI net water rating | 121 MBH | Net AHRI rating based on a piping and pickup allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the I&O ratings table. |
| Domestic hot water | ||
| Domestic hot water | On demand from the combi's DHW circuit | Combi models produce DHW directly; the I&O ratings list 3/4" DHW water connections for combi units. |
| Venting and air | ||
| Venting | Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel | In Canada, plastic venting must be a ULC S636-certified system. |
| Max. equivalent vent/air length, 2" | 60 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Max. equivalent vent/air length, 3" | 100 ft | Table 3D (air intake/vent piping sizes), I&O manual. |
| Physical and connections | ||
| Water content | 2 gal | Per the I&O ratings table. |
| Space-heating water connections | 1" NPT | Noble ratings: NPT connections are used on combi units, sweat connections on the boiler. |
| DHW water connections | 3/4" | Combi-only, per the I&O ratings table (NPT = combi). |
| Gas connection | 1/2" | Per the I&O ratings table. |
Manuals
Alerts documented for this model
- Memory Error
- Fan Speed
- LWCO
- Flame Sequence
- Outlet ARHL
- Air Pressure Switch
- AUX Limit Fault
- Flame Fail: Running
- Flame Fail: Ignition
- Flue Temp Limit
- Flue Temp High
- Outlet MRHL
- Outlet Temp High
- Outlet Temp DIFF
- Flue Sensor Fault
- Outlet Sensor Fault
- Inlet Sensor Fault
- Set Point Met
- Anti-Cycling
- Delta T High
- Low Voltage
- No Flue Temp Change
- Combi Sensor Fault (Combi Only)
- Lockout Inlet Sensor Fault
- Outdoor Sensor Missing
- No Hot Water at Faucets (Combi Only)
- DHW Water is not Hot Enough (Combi Only)
- Combi Boiler is Running but Does Not Supply Heated Water to Space Heating System (Combi Only)
- Space Heating System Heat Emitters Get Hot During a DHW Draw and the Combi Boiler does not Provide Hot Enough Domestic Hot Water (Combi Only)
- Lockout! Water Press Switch
Frequently asked questions
How does the NCF150 compare with the NKC150?
Ratings and connections are the same — 15 to 150 MBH input, 139 MBH DOE capacity, 1" NPT space heating and 3/4" DHW — the NKC150 hangs on a wall and the NCF150 stands on the floor.
What venting does the NCF150 allow?
2" pipe to 60 equivalent feet or 3" pipe to 100 equivalent feet, per Table 3A of the Noble I&O manual.
Questions about the Lochinvar Noble NCF150?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Lochinvar Noble NCF110 vs NCF150Comparison
- Lochinvar Noble NCF150 vs NCF199Comparison
- Lochinvar Noble NKB080Same series
- Lochinvar Noble NKB110Same series
- Lochinvar Noble NKB150Same series
- Lochinvar Noble NKB199Same series
- Lochinvar Noble NKC110Same series
- Lochinvar Noble NKC150Same series
- Lochinvar Noble NKC199Same series
- Lochinvar Noble NCF110Same series
- Lochinvar Noble NCF199Same series
- Noble Fire Tube (NKB/NKC/NCF) series hub