Lochinvar Noble NKC110 vs NKC150

Verdict in brief

The Noble NKC110 and NKC150 are the two smaller wall-hung Noble combis and share the 1" NPT space-heating and 3/4" DHW connections, 95.0% AFUE and on-demand hot water. The 150 fires 15 to 150 MBH against the 110's 11 to 110, adds 37 MBH of DOE capacity, and its 2" vent allowance drops from 100 to 60 equivalent feet.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Noble NKC110 and Lochinvar Noble NKC150
SpecificationLochinvar Noble NKC110Lochinvar Noble NKC150
Heating input, minimum11 MBH15 MBH
Heating input, maximum110 MBH150 MBH
DOE heating capacity102 MBH139 MBH
AHRI net water rating89 MBH121 MBH
Efficiency (AFUE)95 %95 %
Water content1.4 gal2 gal
Space-heating water connections1" NPT1" NPT
DHW water connections3/4"3/4"
Gas connection1/2"1/2"
Max. equivalent vent/air length, 2"100 ft60 ft
Max. equivalent vent/air length, 3"100 ft100 ft
Domestic hot waterOn demand from the combi's DHW circuitOn demand from the combi's DHW circuit

What actually separates them

Both NKC models are wall-hung combis that produce domestic hot water on demand, with 1" NPT space-heating connections, 3/4" DHW connections, a 1/2" gas connection and the SMART CONTROL's diverter logic that Lochinvar's copy credits with eliminating the cold-water "sandwich" during DHW draws.

The 110 product page quotes DHW of up to 2.6 GPM at a 77°F rise; Lochinvar does not print a per-model DHW flow for the 150 in the same spec format, so the 150's extra input should be treated as heating-side headroom first. DOE capacity rises from 102 to 139 MBH between the two.

Venting is the measurable step: 2" pipe reaches 100 equivalent feet on the 110 but only 60 on the 150, with 3" at 100 feet on both. Water content grows from 1.4 to 2.0 gallons.

CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The Noble NKC110 is the entry Noble wall-hung combi: 11 to 110 MBH input at 95.0% AFUE, rated for DHW of up to 2.6 GPM at a 77°F rise, with 3/4" DHW connections.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The Noble NKC150 is the 150 MBH Noble wall-hung combi: 15 to 150 MBH space-heating input at 95.0% AFUE with 139 MBH DOE capacity and a 2-gallon water content.

Natural gasPropaneCombi

Frequently asked questions

Do the NKC110 and NKC150 connect the same way?

Yes — both use 1" NPT space-heating connections and 3/4" DHW connections with a 1/2" gas connection, per the Noble ratings table.

When should I choose the NKC150?

When the heat-loss calculation approaches or exceeds 110 MBH. The NKC110 already covers the small-to-mid home and its DHW rating is quoted on the product page; the 150 adds heating headroom.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate